16 BIT DATA ACQUISITION BOARD
WITH 16 INPUT AND
2 ANALOG OUTPUTS
MODEL DAQ-16162-FW
(NI DAQPad-6052E)
Features
Two 16-bit analog outputs, 8 digital
I/O lines, two 24-bit counters
NI-DAQ driver software to simplify
configuration and measurements
Four analog input signal ranges
NIST-traceable calibration certificate
Digital and or analog triggering
SPECIFICATIONS
Bus
Analog
Inputs
Resolution
Sampling
Rate S/s
Input
Range
Analog
Outputs
Resolution
Output
Rate
Output
Range
Digital
I/O
Counter/
Timers
Triggers
FW
16 SE/8/DI
16 bits
333 kS/s
±.05
to ±10V
2
16 bits
333
kS/s
±10V
8
2, 24-bit
Analog
&
Digital
10 kS/s maximum
when using the single ended DMA channel for for analog ouput.
1 kS/s maximum when using the single DMA channel for either
for either analog input or counter / timer operation.
ANALOG INPUT ACCURACY
SPECIFICATIONS
Nominal
Range (V)
Absolute
Accuracy
Relative Accuracy
%
of
Reading
Offset
(uV)
Noise
+ Quantizatiom (uV)
Temp
Drift
(%/C)
Absolute Accuracy
at Full Scale (mV)
Resolutin
(uV)
Positive
FS
Negative
FS
24 Hrs
1
year
Single Pt.
Averaged
Single Pt.
Averaged
10.0
-10.0
.035
.037
947
981
87
.00006
4.747
1145
115
5.0
-5.0
.005
.007
476
491
43.5
.00001
.876
573
57.3
2.5
-2.5
.035
.037
245
245
21.7
.00006
1.190
286
28.6
1.0
-1.0
.035
.037
99
98
8.7
.00006
.479
115
11.5
Note: Accuracies are
valid for measurements following internal calibration. Averaged
numbers assume dithering and averaging of 100 single readings.
Measurements accuracies are listed for operational temperatures
within ± 1 degree C of internal calibration temperature
and ± 10 degreesc of external or factory calibration
temperature. One year calibration interval recommended. The
Absolute Accuracy at Full Scale calculations were performed
for a maximum range input voltage, 10 (for example, 10V range
for ± 10V range) after one year, assuming 100 pt averaging