16 BIT DATA ACQUISITION BOARD
WITH 16 INPUT AND 2 ANALOG OUTPUTS
MODEL DAQ-16162-PCMCIA
(NI DAQCard-6036E)
Features
Two 16-bit analog outputs, 8 digital
I/O lines, two 24-bit counters
NI-DAQ driver software to simplify
configuration and measurements
Digital and or analog triggering
NIST-traceable calibration certificate
Digital and or analog triggering
SPECIFICATIONS
Bus
Analog
Inputs
Resolution
Sampling
Rate S/s
Input
Range
Analog
Outputs
Resolution
Output
Rate
Output
Range
Digital
I/O
Counter/
Timers
Triggers
PCMCIA
16 SE/8/DI
16 bits
200 kS/s
±.05
to ±10V
2
16 bits
10 kS/s
±10V
8
2, 24-bit
Digital
10 kS/s
maximum when using the single ended DMA channel for for analog
ouput. 1 kS/s maximum when using the single DMA channel for
either for either analog input or counter / timer operation.
ANALOG
INPUT ACCURACY SPECIFICATIONS
Nominal
Range (V)
Absolute
Accuracy
Relative
Accuracy
%
of
Reading
Offset
(mV)
Noise
+ Quantizatiom (mV)
Temp
Drift
(%/C)
Absolute
Accuracy
at Full Scale (mV)
Resolutin
(mV)
Positive
FS
Negative
FS
24
Hrs
1
year
Single
Pt.
Averaged
Single
Pt.
Averaged
10.0
-10.0
.0872
.0914
2.93
.89
.078
.0010
12.154
1.03
.10
5.0
-5.0
.0272
.0314
1.48
.44
.039
.0005
3.087
.51
.051
.5
-.5
.0872
.0914
.167
.053
.005
.0010
.629
.063
.006
.05
-.05
.0872
.0914
.063
.026
.003
.0010
.084
.034
.003
Note: Accuracies are
valid measurements following internal calibration. Averaged
numbers assume dithering and averaging of 100 single readings.
Measurements accuracies are listed for operational temperatures
within ± degree C of internal calibration temperature
and ± 10 degreesc of external or factory calibration
temperature. One year calibration interval recommended. The
Absolute Accuracy at Full Scale calculations were performed
for a maximum range input voltage, 10 (for example, 10V range
for ± 10V range) after one year, assuming 100 pt averaging
of data.
Order
Code Model
Capacity
Range
Description
Price
Quantity