The DAQ-SCC-SG24 module is
a
dual channel conditioning module for
full bridge strain gauge load cell and/
or torque transducers. Each channel
DAQ-SCC-SG24 module includes
an instrumentation amplifier, a 1.6kHz
low pass filter, and a potentiometer
for bridge offset nulling. Each module
also includes a single 10 Volt excitation
source.
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
SPECIFICATIONS
Number of channels:
2 differential
Input signal range:
±100 mV
Output signal range:
±10 V
Gain:
100
Overvoltage protection:
±42 Vpk/60 VDC
Input impedance:
10 Mohm powered on 10 kohm powered off or overload
Gain error:
±.05% of FS
Gain: error:
±.8% of reading maximum
Offset error:
±5uV
Bandwidth:
1.6 kHz (single pole RC filter)
Excitation voltage:
10 V ±0.4%
Excitation current Drive:
42 mA, based on two full bridge1 20 ohm strain gauges
Excitation drift:
13 mV/degrees C
Power Requirements
Analog:
103mW
Digital:
115 mW
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
PORTABLE MODULAR SIGNAL CONDITIONING MODULES
MODEL DAQ-SCC-SG24
The DAQ-SCC-SG24 module is
a
dual channel conditioning module for
full bridge strain gauge load cell and/
or torque transducers. Each channel
DAQ-SCC-SG24 module includes
an instrumentation amplifier, a 1.6kHz
low pass filter, and a potentiometer
for bridge offset nulling. Each module
also includes a single 10 Volt excitation
source.
SPECIFICATIONS
Number of channels:
2 differential
Input signal range:
±100 mV
Output signal range:
±10 V
Gain:
100
Overvoltage protection:
±42 Vpk/60 VDC
Input impedance:
10 Mohm powered on 10 kohm powered off or overload
Gain error:
±.05% of FS
Gain: error:
±.8% of reading maximum
Offset error:
±5uV
Bandwidth:
1.6 kHz (single pole RC filter)
Excitation voltage:
10 V ±0.4%
Excitation current Drive:
42 mA, based on two full bridge1 20 ohm strain gauges