DPM-3-TRES TEDS Reader Editor Software
 
Used along with a DPM-3 and a Serial Data Communication Board to Read and Edit
Plug and Play TEDS Smart Sensors.
 

Read and Edit Plug and Play Smart Sensors with TEDS

 
 
Computer connected to DPM-3 via RS-232
 
The DPM-3-TRES TEDS Reader Editor software was developed to read and edit Plug and Play Smart Sensos that are compliant to the IEEE 1451.4 Standard. TEDS, or Transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type, excitation, etc. This information is stored in an EEPROM chip attached to the sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter (DPM-3), thereby easing automatic system configuration.


Order Code Model Capacity Range Description Price Quantity Add to Cart
DPM-3-TRES N/A TEDS Reader Editor Software $150
Click on any of the reduced screens for a full-size screen view.
 
  TEDS Reader Editor Software
  Communications

Click on the appropiate serial communication Bus type.
  Com Ports and Baud Rates

Click to choose the appropiate Com Port and Baud
Rate then click on the Establish button.
  Establish Communication

If Communication has been established the Com Port and Baud Rate will be displayed in a window with a green background. If a TEDS EEPROM is detected it will be displayed in a lower window with a green background. At this point click the Continue button.
 

Blank IEEE 1451.4 template

You can populate the template by a file or by a DPM-3 meter. To populate by a DPM-3 meter, at the top of the screen in the Menu bar, click on Meter and then click Read.

 

  Populated IEEE 1451.4 template

This IEEE 1451.4 template was populated via a DPM-3 meter by clicking on Meter and then Read in the Menu bar at the top of the screen.
  Editing a IEEE 1451.4 template

This screen shows an example of changing units from pounds to newtons. Once the template data has been edited click on Meter and then Write in the Menu bar at the top of the screen. A pop-up warning screen will then appear click on yes.
  Newly Populated IEEE 1451.4 template

This screen shows the newly edited IEEE 1451.4 template.
  Instruction Screen

Pressing on Instructions on the top menu bar brings an instruction screen, avoiding the need for a printed manual for the TEDS Reader Editor Software.


Order Code Model Capacity Range Description Price Quantity Add to Cart
DPM-3-TRES N/A TEDS Reader Editor Software $150
DPM-3-TRES TEDS Reader Editor Software
 
Used along with a DPM-3 and a Serial Data Communication Board to Read and Edit
Plug and Play TEDS Smart Sensors.
 

Read and Edit Plug and Play Smart Sensors with TEDS

 
 
Computer connected to DPM-3 via RS-232
 
The DPM-3-TRES TEDS Reader Editor software was developed to read and edit Plug and Play Smart Sensos that are compliant to the IEEE 1451.4 Standard. TEDS, or Transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type, excitation, etc. This information is stored in an EEPROM chip attached to the sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter (DPM-3), thereby easing automatic system configuration.

Click on any of the reduced screens for a full-size screen view.
 
  TEDS Reader Editor Software
  Communications

Click on the appropiate serial communication Bus type.
  Com Ports and Baud Rates

Click to choose the appropiate Com Port and Baud
Rate then click on the Establish button.
  Establish Communication

If Communication has been established the Com Port and Baud Rate will be displayed in a window with a green background. If a TEDS EEPROM is detected it will be displayed in a lower window with a green background. At this point click the Continue button.
 

Blank IEEE 1451.4 template

You can populate the template by a file or by a DPM-3 meter. To populate by a DPM-3 meter, at the top of the screen in the Menu bar, click on Meter and then click Read.

 

  Populated IEEE 1451.4 template

This IEEE 1451.4 template was populated via a DPM-3 meter by clicking on Meter and then Read in the Menu bar at the top of the screen.
  Editing a IEEE 1451.4 template

This screen shows an example of changing units from pounds to newtons. Once the template data has been edited click on Meter and then Write in the Menu bar at the top of the screen. A pop-up warning screen will then appear click on yes.
  Newly Populated IEEE 1451.4 template

This screen shows the newly edited IEEE 1451.4 template.
  Instruction Screen

Pressing on Instructions on the top menu bar brings an instruction screen, avoiding the need for a printed manual for the TEDS Reader Editor Software.