CALL TO INQUIRE ABOUT EDUCATIONAL DISCOUNTS
Load Cell
Customer Account Information
HOME  |  PRODUCTS  |  TECH SUPPORT  |  ABOUT US  |  CONTACT US |                              
View Cart Checkout   
SEARCH
  
Advanced Search

TECH SUPPORT
Online Manuals
Wiring / Color Code
Calibration Certificates
Load Cell Troubleshooting
Warranty / Repair
Load Cell Terminology
Calculators
Free Load Cell Catalog
Track Your Order
Learn about Plug and Play Smart Sensors

We gladly accept:
 View Cart
 Checkout

MINI LOAD COLUMN LOAD CELL
COMPRESSION ONLY

MLC SERIES LOAD CELL

CAPACITY RANGES:
2,000, 3,000, 5,000, 7,500, 10,000,
15,000, 20,000, 30,000 LBS.





The MLC Series is our miniature high capacity
compression only load cell/force sensor, featuring
low profile compact size for a wide range of portable
and dedicated applications up to 30,000 lbs. The load
diameter is slightly convex for accurate load distribution.
Low deflection through design results in ultra fast
frequency response. The MLCs are designed to be
mounted in a shallow machined flat pocket or smooth
flat surface, either free or fastened via a bottom 6-32
tapped hole. These load cells are manufactured from
heat treated 17-4 ph stainless steel. The sensing
element incorporates bonded foil strain gages of the
highest quality and are sealed for protection against
most industrial Environments.







      SPECIFICATIONS  
 
  Rated Output (R.O.):   2 mV/V nominal  
  Nonlinearity:   0.25% of R.O.  
  Hysteresis:   0.25% of R.O  
  Nonrepeatability:   0.1% of R.O.  
  Zero Balance:   1.0% of R.O.  
  Compensated Temp.   Range:   60° to 160°F  
  Safe Temp. Range:   -65° to 200°F  
  Temp. Effect  on Output:   0.005% of Load/°F  
  Temp. Effect on Zero:   0.01% of R.O./°F  
  Terminal Resistance:   350 ohms nominal  
  Excitation Voltage:   10 VDC  
  Safe Overload:   150% of R.O.  
 


DIMENSIONS (INCHES)
MODEL  CAPACITY 
LBS.
D1 D2 H1 H2 H3 BUTTON
RADIUS
 DEFLECTION 
INCHES
MLC-2K  2,000  .625  .450  .600  .480  .06  2.00 0.002
MLC-3K  3,000  .625  .450  .600  .480  .06  2.00 0.002
MLC-5K  5,000  .625  .450  .600  .480  .06  2.00 0.002
MLC-7.5K  7,500  .875  .625  .625  .505  .06  2.00 0.002
MLC-10K  10,000  .875  .625  .625  .505  .06  2.00 0.002
MLC-15K  15,000  1.250  .875  1.000  .880  .06  4.00 0.002
MLC-20K  20,000  1.250  .875  1.000  .880  .06  4.00 0.002
MLC-30K  30,000  1.250  .875  1.000  .880  .06  4.00 0.002

 

Order Code Model Capacity Range Description Price Quantity Add to Cart
MLC-2K Capacity: 2,000 lbs Mini Comp Load Column $400
MLC-3K Capacity: 3,000 lbs Mini Comp Load Column $400
MLC-5K Capacity: 5,000 lbs Mini Comp Load Column $400
MLC-7.5K Capacity: 7,500 lbs Mini Comp Load Column $450
MLC-10K Capacity: 10,000 lbs Mini Comp Load Column $450
MLC-15K Capacity: 15,000 lbs Mini Comp Load Column $550
MLC-20K Capacity: 20,000 lbs Mini Comp Load Column $550
MLC-30K Capacity: 30,000 lbs Mini Comp Load Column $550
CAL-TEDS N/A Plug & Play Option with Connector $55

 

[Close Box]

ACCESSORIES

CAL-TEDS
Plug & Play Option

AD9 (9 PIN "D" Series) Connector attached to the end of a Load Cell or Torque sensor cable with a TEDS ( Transducer Electoric Data Sheet ) EPPROM. Used with a DPM-3 Load Cell Meter, the Load Cell and DPM-3 will self calibrate. This option is a real time saver. Learn about Plug & Play Smart Sensors.

 

[Close Box]  

Learn about Plug and Play Smart Sensors


What are Plug and Play Smart Sensors?

A Plug and Play Smart Sensor is a Sensor that is compliant to the IEEE 1451.4 Standard. TEDS, or Transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type, excitation, etc. This information is stored in an EEPROM chip attached to a sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter, thereby easing automatic system configuration. Let's say you have a Transducer Techniques Load Cell or Torque Sensor with the the proper instrument IEEE 1451.4 enabled Load Cell or Torque Sensor could be swapped in, self-identify, and work appropriately.


What are the advantages of Plug and Play Smart Sensors?

Benefits that can be experienced now include:

  • Simplified troubleshooting
  • Reduced safety risks. It is no longer necessary to "climb on machines" for connection verification
  • Reduced costs for set-up and tear-down
  • No recalibration is needed when replacing sensors
  • The data acquisition system can recalibrate itself

Advantages that will be available in the future include:

  • Integration with wireless transceivers
  • Elimination of large lengths of analog wiring
  • Reduced installation, maintenance and upgrade costs of measurement and control systems
  • The opportunity to add intelligence to sensors

Can a legacy / non-TEDS sensor be converted to a TEDS "Plug and Play" sensor?

Yes. A legacy / non-TEDS sensor can be converted to a TEDS "Plug and Play" sensor. Transducer Techniques offers a CAL-TEDS service to convert your sensor to a TEDS "Plug and Play" compliant sensor. The service consists of a connector, recalibration and a programmed EEPROM. This will update a legacy / non-TEDS sensor to be capable of plugging into Transducer Techniques IEEE 1451.4 compliant DPM-3 Smart Load Cell Meter.


What is Virtual TEDS?

Virtual TEDS is an online library of data sheets developed by National Instruments (www.ni.com) that contain the same information that would be found in an EEPROM TEDS, but exist for sensors not containing the EEPROM. This would define Plug and Play capability for legacy / non-TEDS sensors. As a National Instruments Plug and Play Sensor Partner and a National Instruments Alliance Member, Transducer Techniques has contributed the data for all its sensors to the Virtual TEDS database.


What parameters are included on a Transducer Techniques TEDS chip?

TEDS Item Values
Manufacturer ID Transducer Techniques (ID#42)
Model Number 28
Version Letter A
Version Number 3
Serial Number 149087
Transducer Electrical Signal Type Bridge Sensor
Minimum Physical Value 0 lb
Maximum Physical Value 100 lb
Minimum Electrical Value 0 V/V
Maximum Electrical Value .0024709 V/V
Mapping Method Linear
Bridge Type Full
Impedance of Each Bridge Element 350 Ohm
Response Time .000001 sec
Excitation Level (Nominal) 10 V
Excitation Level (Minimum) 1 V
Excitation Level (Maximum) 12 V
Calibration Date 1/1/2004
Calibration Initials RAB
Calibration Period (Days) 365 days
Measurement Location ID 0
Users Data Thank You From TTI
[Close Box]  
[Close Box]

ACCESSORIES

CAL-TEDS
Plug & Play Option

AD9 (9 PIN "D" Series) Connector attached to the end of a Load Cell or Torque sensor cable with a TEDS ( Transducer Electoric Data Sheet ) EPPROM. Used with a DPM-3 Load Cell Meter, the Load Cell and DPM-3 will self calibrate. This option is a real time saver. Learn about Plug & Play Smart Sensors.

 

[Close Box]  

Learn about Plug and Play Smart Sensors


What are Plug and Play Smart Sensors?

A Plug and Play Smart Sensor is a Sensor that is compliant to the IEEE 1451.4 Standard. TEDS, or Transducer Electronic Data Sheet, is a set of electronic data in a standardized format defined within the IEEE 1451.4 standard. This data specifies what type of sensor is present, describes its interface, and gives technical information such as sensitivity, bridge type, excitation, etc. This information is stored in an EEPROM chip attached to a sensor. By having this chip, the sensor can identify and describe itself to the network and or Smart Load Cell Meter, thereby easing automatic system configuration. Let's say you have a Transducer Techniques Load Cell or Torque Sensor with the the proper instrument IEEE 1451.4 enabled Load Cell or Torque Sensor could be swapped in, self-identify, and work appropriately.


What are the advantages of Plug and Play Smart Sensors?

Benefits that can be experienced now include:

  • Simplified troubleshooting
  • Reduced safety risks. It is no longer necessary to "climb on machines" for connection verification
  • Reduced costs for set-up and tear-down
  • No recalibration is needed when replacing sensors
  • The data acquisition system can recalibrate itself

Advantages that will be available in the future include:

  • Integration with wireless transceivers
  • Elimination of large lengths of analog wiring
  • Reduced installation, maintenance and upgrade costs of measurement and control systems
  • The opportunity to add intelligence to sensors

Can a legacy / non-TEDS sensor be converted to a TEDS "Plug and Play" sensor?

Yes. A legacy / non-TEDS sensor can be converted to a TEDS "Plug and Play" sensor. Transducer Techniques offers a CAL-TEDS service to convert your sensor to a TEDS "Plug and Play" compliant sensor. The service consists of a connector, recalibration and a programmed EEPROM. This will update a legacy / non-TEDS sensor to be capable of plugging into Transducer Techniques IEEE 1451.4 compliant DPM-3 Smart Load Cell Meter.


What is Virtual TEDS?

Virtual TEDS is an online library of data sheets developed by National Instruments (www.ni.com) that contain the same information that would be found in an EEPROM TEDS, but exist for sensors not containing the EEPROM. This would define Plug and Play capability for legacy / non-TEDS sensors. As a National Instruments Plug and Play Sensor Partner and a National Instruments Alliance Member, Transducer Techniques has contributed the data for all its sensors to the Virtual TEDS database.


What parameters are included on a Transducer Techniques TEDS chip?

TEDS Item Values
Manufacturer ID Transducer Techniques (ID#42)
Model Number 28
Version Letter A
Version Number 3
Serial Number 149087
Transducer Electrical Signal Type Bridge Sensor
Minimum Physical Value 0 lb
Maximum Physical Value 100 lb
Minimum Electrical Value 0 V/V
Maximum Electrical Value .0024709 V/V
Mapping Method Linear
Bridge Type Full
Impedance of Each Bridge Element 350 Ohm
Response Time .000001 sec
Excitation Level (Nominal) 10 V
Excitation Level (Minimum) 1 V
Excitation Level (Maximum) 12 V
Calibration Date 1/1/2004
Calibration Initials RAB
Calibration Period (Days) 365 days
Measurement Location ID 0
Users Data Thank You From TTI
[Close Box]  
© Copyright 2008 Transducer Techniques, Inc., All Rights Reserved.