The SSI is a TEDS IEEE 1451.4 compliant portable hand held smart sensor indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self calibrate. When using a non-TEDS Load Cell or Torque Sensor the SSI can be setup by simple front panel push buttons. The SSI can be scaled to a full five digits from 0 to 99,999 to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak, and or valley testing. The SSI also features an RS-232 port for data logging to a PC. You can also log data to the SSI’s internal memory. You can store up to 8,000 time and date stamped readings. The SSI also features 2 built-in, solid-state alarm relays, with LED and Audible indications. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications were the SSI is mounted permanently.
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
Options
FEATURES
Approved
Plug & Play” operation with automatic scaling at power-up with TEDS IEEE 1451.4
compliant load cells.
Menu-driven scaling of non-TEDS-compliant load cells via keypad with a choice of tw
scaling methods: manually entered coordinates of two points, or reading coordinates
of two points using input signals.
PC-based scaling of non-TEDS-compliant load cells using Instrument Setup software,
again with a choice of two scaling methods.
Keypad selectable units of measure for load, torque or pressure, with automatic conversion
of readings between units.
Lockout feature to simplify meter operations and prevent inadvertent changes.
Ultra-fast signal sampling rate of 15,360 samples/second (when set for 60 Hz noise
rejection) or 12,800 samples/second (when set for 50 Hz noise rejection).
Normal conversion rate of 60/second (when set for 60 Hz noise rejection) or
50/second (when set for 50 Hz noise rejection), with digital averaging of every 256
samples. Allows display of filtered or unfiltered readings, capture of Peak, First Peak
or Valley.
Selectable Fast conversion rates up to 7,680/second (when set for 60 Hz noise
rejection) or 6,400/second (when set for 50 Hz noise rejection). Always unfiltered,
allows capture of Peak or First Peak.
Display update rate at 3.75/second (when set for 60 Hz noise rejection) or
3.125/second (when set for 50 Hz noise rejection). Display batch averages of 16
conversions or moving averages of conversions.
RS-232 port for direct connection to a PC at baud rates from 300/second to
38.4k/second.
Data logging to internal memory of up to 8,000 time and date stamped displayed
readings at up to 60 or 50 captures/second. Data logging may be single or continuous.
Selectable memory protection to prevent overwriting previously stored data.
Recall of internally stored readings to the meter display, a PC, or a printer with an
RS-232 interface. Recall may be single or continuous (standard capability).
Recall of last meter calibration date.
Data logging of time and date stamped values in real time via RS-232 (standard) to a
PC or printer. The values may be the current reading, Peak, Valley, or any combination
thereof.
Optional PC Data Logging Software, P/N SSI-DLS. Collects real-time or stored data
via RS-232. Lists, plots or stores meter data in PC memory.
Two built-in, solid state alarm relays, with LED and audible indications. Selectable
relay latching or non-latching, setpoint hysteresis or band deviation modes.
Two control inputs assignable to Meter Reset, Peak & Valley Reset, Peak & Valley
Display, Tare, Tare Reset, and Log Trigger.
Built-in load cell excitation voltage.
Powered by a rechargeable 2400 mAh lithium-ion battery for up to 65 hours of operation.
Battery charge monitor circuit with bar graph and audible indications.
Selectable automatic meter shutoff after interval of inactivity (15, 30 or 60 minutes).
Wall plug type, UL-rated AC adapter / battery charger unit
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
Options
SPECIFICATIONS
Display
Type:
Reflective
LCD, 2.56” x 1.73” (65 x 44 mm) window
Main numeric
display:
6 seven-segment digits, 0.57”
(14.5 mm) high
Other displayed
items:
4-digit recall number,
10-segment bar graph, choice of
18 units
of measure, battery
life indicator, operating mode indicator
Overload
indication:
Display
flashes at 120% of HiRead
Response Rates
Normal data sampling rate:
15,360 samples/second
(setting for 60 Hz noise rejection) 12,800 samples/second
(setting for 50 Hz
noise rejection)
Normal conversion rate:
Every
256 samples
60/second (setting for 60 Hz noise
rejection)
50/second (setting for 50 Hz noise
rejection)
Fast conversion rates:
Every 2 to 128 samples
(programmable)
Relay response rate:
Same as Normal
conversion rate
Display update rate:
Every
16 conversions
3.750/second (setting for 60 Hz noise
rejection)
3.125/second (setting for 50 Hz noise
rejection)
Peak & valley capture rate
(selectable):
Every 2, 4, 8, 16, 32, 64, 128 or 256 samples
Peak & valley display update rate:
3.750/second (setting for 60 Hz noise rejection)
3.125/second
(setting for 50 Hz noise rejection)
Analog-to-Digital Conversion
Recommended load:
120-1000 ohm bridge
Bridge excitation voltage:
3.0V
Provision for variations in bridge
excitation:
Ratiometric operation
Signal span,
max:
15 mV
Transducer sensitivity range:
1-5
mV / V
A-to-D converter resolution:
16 bits
(65,536 counts)
Signal resolution:
0.5 μV/count
Accuracy at
25°C:
±1.5 μV
Span Tempco:
0.0015% of reading/°C
Zero Tempco:
0.2
μV/°C
NMR with no filtering:
90 dB
Signal filtering (selectable):
1) No filtering: 50 or 60
conversions/second
2) Batch average of 16 conversions
3) Moving average of conversions
Power Requirements
Internal
battery:
Rechargeable
lithium ion
Battery capacity
(nominal):
2400
mAh, 3.7V
RUN time on single battery charge:
Up to 65 hours with 350 ohm bridge
Battery charger:
Wall plug AC power unit
Batter charger
input:
100-240V ac, 50/60 Hz, 0.4A
Batter charger
output:
5.0V
dc, 1.0A
Battery charging time,
max:
8
hours
Battery charge
indication:
Battery symbol with 4 bars to show percent of full
charge 4 bars = 80% - 100%, 3 bars = 60% - 80%,
2 bars = 40% - 60%, 1 bar = 20% - 40%, flashing battery symbol = 0% - 20%
Relay Output
Relay
types:
Dual relays
with single common, solid state
AC
rating:
120 mA @ 350Vac peak,
35 ohms series resistance
DC rating
:
120 mA @ 350Vdc, 35
ohms series resistance
Isolation to signal
common:
5300 Vac rms
Setpoint
setup:
Via keypad or RS-232
Response rate (selectable):
60/second or 50/second (each 1 conversion or 256 samples)
Response filtering
(selectable):
Filtered or unfiltered
Active modes (selectable):
Above or below setpoint, latching or non-latching, disabled
Visual active Alarm Indication:
AL1 LED (yellow), AL2 LED (red), Go (green) 2 8 -
Audible active alarm indication:
Selectable
Activation time delay
(selectable):
1
to 128 conversions
Setpoint / lockout modes (selectable):
1) Display and change setpoints
2) Display but do not change setpoints
3)
Neither display nor change setpoints
Serial Interface to PC
Signal levels:
RS-232
Signal grounding:
Same
ground as load cell signal
Baud rates (selectable):
300, 600, 1200, 2400, 4800, 9600, 19200,
38400
Serial
protocol:
Point-to-point
ASCII, PC compatible
Control Inputs
Number of inputs:
2 (A & B)
Input activation:
Short
to ground
Control input action:
Meter reset,
function reset, display Peak or Valley, tare, tare reset, Log
Mechanical
Dimensions:
1.28” x 3.30” x 7.50” (32 x 84 x 185 mm)
Weight:
10 oz (280 g)
Case material:
ABS-94HB
plastic
Provision for
stand:
3 stainless steel inserters, 8-32 UNC
threads, 3/8” deep
1.500” triangle base, 1.750 triangle height (see photo on page 6)
Keypad:
Membrane
type, 8-keys with tactile feedback
Display
type:
Reflective LCD
Displayed info:
6 large digits,
4 small digits, two bar graphs, units of measure, indicators
Electrical connectors:
DB9 male for TEDS and signal connection to load
cell,
3-pin jack plus detachable connector for
dual relay output,
6-pin RJ11 jack for RS-232 link to
computer,
Coaxial connector for external power
unit
Environmental
Operating temperature:
0°C to 55°C
Storage temperature:
-20°C to 60°C
Relative humidity:
95% from 0°C to
40°C, non-condensing
Environmental sealing:
Dust and
humidity resistant
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
Options
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT
$395
»More info
SSI-RJ11AD9
SSI-AMB
RS232 Connector
Adjustable Mounting Bracket
SSI-TRES
SSI-DLS
TEDS Reader_Editor Software
Data Logging Software
SMART PLUG & PLAY PORTABLE HAND HELD INDICATOR
MODEL SSI
The SSI is a TEDS IEEE 1451.4 compliant portable hand held smart sensor indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self calibrate. When using a non-TEDS Load Cell or Torque Sensor the SSI can be setup by simple front panel push buttons. The SSI can be scaled to a full five digits from 0 to 99,999 to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak, and or valley testing. The SSI also features an RS-232 port for data logging to a PC. You can also log data to the SSI’s internal memory. You can store up to 8,000 time and date stamped readings. The SSI also features 2 built-in, solid-state alarm relays, with LED and Audible indications. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications were the SSI is mounted permanently.
FEATURES
Approved
Plug & Play” operation with automatic scaling at power-up with TEDS IEEE 1451.4
compliant load cells.
Menu-driven scaling of non-TEDS-compliant load cells via keypad with a choice of tw
scaling methods: manually entered coordinates of two points, or reading coordinates
of two points using input signals.
PC-based scaling of non-TEDS-compliant load cells using Instrument Setup software,
again with a choice of two scaling methods.
Keypad selectable units of measure for load, torque or pressure, with automatic conversion
of readings between units.
Lockout feature to simplify meter operations and prevent inadvertent changes.
Ultra-fast signal sampling rate of 15,360 samples/second (when set for 60 Hz noise
rejection) or 12,800 samples/second (when set for 50 Hz noise rejection).
Normal conversion rate of 60/second (when set for 60 Hz noise rejection) or
50/second (when set for 50 Hz noise rejection), with digital averaging of every 256
samples. Allows display of filtered or unfiltered readings, capture of Peak, First Peak
or Valley.
Selectable Fast conversion rates up to 7,680/second (when set for 60 Hz noise
rejection) or 6,400/second (when set for 50 Hz noise rejection). Always unfiltered,
allows capture of Peak or First Peak.
Display update rate at 3.75/second (when set for 60 Hz noise rejection) or
3.125/second (when set for 50 Hz noise rejection). Display batch averages of 16
conversions or moving averages of conversions.
RS-232 port for direct connection to a PC at baud rates from 300/second to
38.4k/second.
Data logging to internal memory of up to 8,000 time and date stamped displayed
readings at up to 60 or 50 captures/second. Data logging may be single or continuous.
Selectable memory protection to prevent overwriting previously stored data.
Recall of internally stored readings to the meter display, a PC, or a printer with an
RS-232 interface. Recall may be single or continuous (standard capability).
Recall of last meter calibration date.
Data logging of time and date stamped values in real time via RS-232 (standard) to a
PC or printer. The values may be the current reading, Peak, Valley, or any combination
thereof.
Optional PC Data Logging Software, P/N SSI-DLS. Collects real-time or stored data
via RS-232. Lists, plots or stores meter data in PC memory.
Two built-in, solid state alarm relays, with LED and audible indications. Selectable
relay latching or non-latching, setpoint hysteresis or band deviation modes.
Two control inputs assignable to Meter Reset, Peak & Valley Reset, Peak & Valley
Display, Tare, Tare Reset, and Log Trigger.
Built-in load cell excitation voltage.
Powered by a rechargeable 2400 mAh lithium-ion battery for up to 65 hours of operation.
Battery charge monitor circuit with bar graph and audible indications.
Selectable automatic meter shutoff after interval of inactivity (15, 30 or 60 minutes).
Wall plug type, UL-rated AC adapter / battery charger unit
SPECIFICATIONS
Display
Type:
Reflective
LCD, 2.56” x 1.73” (65 x 44 mm) window
Main numeric
display:
6 seven-segment digits, 0.57”
(14.5 mm) high
Other displayed
items:
4-digit recall number,
10-segment bar graph, choice of
18 units
of measure, battery
life indicator, operating mode indicator
Overload
indication:
Display
flashes at 120% of HiRead
Response Rates
Normal data sampling rate:
15,360 samples/second
(setting for 60 Hz noise rejection) 12,800 samples/second
(setting for 50 Hz
noise rejection)
Normal conversion rate:
Every
256 samples
60/second (setting for 60 Hz noise
rejection)
50/second (setting for 50 Hz noise
rejection)
Fast conversion rates:
Every 2 to 128 samples
(programmable)
Relay response rate:
Same as Normal
conversion rate
Display update rate:
Every
16 conversions
3.750/second (setting for 60 Hz noise
rejection)
3.125/second (setting for 50 Hz noise
rejection)
Peak & valley capture rate
(selectable):
Every 2, 4, 8, 16, 32, 64, 128 or 256 samples
Peak & valley display update rate:
3.750/second (setting for 60 Hz noise rejection)
3.125/second
(setting for 50 Hz noise rejection)
Analog-to-Digital Conversion
Recommended load:
120-1000 ohm bridge
Bridge excitation voltage:
3.0V
Provision for variations in bridge
excitation:
Ratiometric operation
Signal span,
max:
15 mV
Transducer sensitivity range:
1-5
mV / V
A-to-D converter resolution:
16 bits
(65,536 counts)
Signal resolution:
0.5 μV/count
Accuracy at
25°C:
±1.5 μV
Span Tempco:
0.0015% of reading/°C
Zero Tempco:
0.2
μV/°C
NMR with no filtering:
90 dB
Signal filtering (selectable):
1) No filtering: 50 or 60
conversions/second
2) Batch average of 16 conversions
3) Moving average of conversions
Power Requirements
Internal
battery:
Rechargeable
lithium ion
Battery capacity
(nominal):
2400
mAh, 3.7V
RUN time on single battery charge:
Up to 65 hours with 350 ohm bridge
Battery charger:
Wall plug AC power unit
Batter charger
input:
100-240V ac, 50/60 Hz, 0.4A
Batter charger
output:
5.0V
dc, 1.0A
Battery charging time,
max:
8
hours
Battery charge
indication:
Battery symbol with 4 bars to show percent of full
charge 4 bars = 80% - 100%, 3 bars = 60% - 80%,
2 bars = 40% - 60%, 1 bar = 20% - 40%, flashing battery symbol = 0% - 20%
Relay Output
Relay
types:
Dual relays
with single common, solid state
AC
rating:
120 mA @ 350Vac peak,
35 ohms series resistance
DC rating
:
120 mA @ 350Vdc, 35
ohms series resistance
Isolation to signal
common:
5300 Vac rms
Setpoint
setup:
Via keypad or RS-232
Response rate (selectable):
60/second or 50/second (each 1 conversion or 256 samples)
Response filtering
(selectable):
Filtered or unfiltered
Active modes (selectable):
Above or below setpoint, latching or non-latching, disabled
Visual active Alarm Indication:
AL1 LED (yellow), AL2 LED (red), Go (green) 2 8 -
Audible active alarm indication:
Selectable
Activation time delay
(selectable):
1
to 128 conversions
Setpoint / lockout modes (selectable):
1) Display and change setpoints
2) Display but do not change setpoints
3)
Neither display nor change setpoints
Serial Interface to PC
Signal levels:
RS-232
Signal grounding:
Same
ground as load cell signal
Baud rates (selectable):
300, 600, 1200, 2400, 4800, 9600, 19200,
38400
Serial
protocol:
Point-to-point
ASCII, PC compatible
Control Inputs
Number of inputs:
2 (A & B)
Input activation:
Short
to ground
Control input action:
Meter reset,
function reset, display Peak or Valley, tare, tare reset, Log
Mechanical
Dimensions:
1.28” x 3.30” x 7.50” (32 x 84 x 185 mm)
Weight:
10 oz (280 g)
Case material:
ABS-94HB
plastic
Provision for
stand:
3 stainless steel inserters, 8-32 UNC
threads, 3/8” deep
1.500” triangle base, 1.750 triangle height (see photo on page 6)
Keypad:
Membrane
type, 8-keys with tactile feedback
Display
type:
Reflective LCD
Displayed info:
6 large digits,
4 small digits, two bar graphs, units of measure, indicators
Electrical connectors:
DB9 male for TEDS and signal connection to load
cell,
3-pin jack plus detachable connector for
dual relay output,
6-pin RJ11 jack for RS-232 link to
computer,
Coaxial connector for external power
unit
Environmental
Operating temperature:
0°C to 55°C
Storage temperature:
-20°C to 60°C
Relative humidity:
95% from 0°C to
40°C, non-condensing
Environmental sealing:
Dust and
humidity resistant
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT