HOME |
PRODUCTS |
TECH SUPPORT |
ABOUT US |
CONTACT US |
View Cart
Checkout
SEARCH
Advanced Search
PRODUCT
CATEGORIES Load Cells / Force Sensors Beam Load Cells Torque Sensors Load Cell Displays
Signal Conditioning Data Acquisition
Software Load Cell Accessories
TECH
SUPPORT
Online Manuals
Wiring / Color Code
Calibration Certificates
Load Cell Troubleshooting
Warranty / Repair
Load Cell Terminology
Calculators
Free Load Cell Catalog
Track Your Order
Learn about Plug and Play Smart Sensors
The TIO-3000 System was originally
designed
to perform precision summing
on 2, 3 , or 4 load
cell signals for
weighing applications.
Development
has progressed into accessory
modules
with considerable versatility for
user
defined configurations in a
compact economical
five (5) slot
system
with built-in meter and
channel
selector.
TMO-3
Amplifier / Conditioner module for strain gage type sensors
SUM-3
Precision Summer for weighing
PKD-3
Peak Hold with polarity and reset
DSP-3
Window Alarm with dual set points
INPUTS
Weight / Force
Pressure
Strain
Deflection
OPTIONAL OUTPUTS
Analog Data
Current Loops
Peak Capture
(.5 ms Response Time)
Control (Alarms)
Quick Look Display
CHASSIS SPECIFICATIONS
SPECIFICATIONS
Plug-In Capacity:
5
Meter:
3 1/2 or 4 1/2 digit
Sensor Input:
9 pin D connector
Data / Control Output:
25 pin D connector
Size (Inches):
12 wide x 7.5 high x 8 deep
Power:
115 VAC 60 Hz
Fuse:
250 mA
AVAILABLE CONFIGURATIONS
Function
TMO-3
(Amp / Cond)
SUM-3
(Sum)
PKD-3
(Peak)
DSP-3
(Alarms)
Capacity
5
4
3
3
2
2
0
1
1
1
1
0
0
0
1
0
0
0
0
0
0
1
2
0
TMO-3 AMPLIFIER/CONDITIONER Description
The TMO-3 Module provides sensor excitation,
zero balance control, gain adjustment and calibration resistor, necessary
to condition one
(1) strain gage type sensor signal for display on built-in meter, off
board recording or processing. The nominal output range of the module
is 0 to ±10 VDC. The TMO-3 module derives its power from the TIO-3000
motherboard. On-board regulators supply amplifier bias and bridge excitation.
Each module contains a two-pole filter as the final element.
Options
1.
A 4 to 20 mA current loop output is available as Option "A".
2.
The standard 16 Hz filter was picked for meter stability.
The bandwidth of the TMO-3 can be much higher if desired.
DSP-3 WINDOW ALARM Description
The DSP-3 is designed as a watchdog module
to monitor critical sensor data from a TMO-3 or SUM-3 Module. The window
is normally associated
with signals such as: below norma (yellow), go range or acceptable
(green), and above acceptable (red). Front edge LED's provide this
status, as do output relays. The window is set by a high and low potentiometer,
with set values displayed on the TIO-3000 meter, usually in a engineering
unit like the sensor channel it is tracking. Output relays can be used
to drive larger external alarm devices or to switch off the process
or activity that is causing the unacceptable level.
Options
1.
Response time 1 ms
MODULE
SPECIFICATIONS
Amplifier Type:
Bipolar differential
Gain Adjustment:
75 to 1000
Input Impedance:
50 megaohm minimum
Output Voltage:
0 to +-10 volts, less
with sum
CMR:
10 dB min., DC to 15 Hz
Noise and Ripple:
Less than 10 mV
Nonlinearity:
.05% of full scale
Compliance:
.1% of full scale
Frequency Response:
DC to 16 Hz
Bridge Resistance:
120 to 1000 ohm
Bal Range (350 ohm):
25% of output,
minimum
Shunt Calibration:
Single point, local
Sensor Wiring:
6 wire shielded
Excitation Type:
Constant 8 VDC
up to 100 mA
Load Regulation:
.1% max for 100%
load charge
MODULE
SPECIFICATIONS
Alarm Settings:
2(high and low)
Status Levels:
3(low, go and high)
Alarm Range:
0 to 5.0 VDC
Alarm Response:
Less than 15 ms
Alarm Settings:
Via TIO-3000 meter
Power:
Via TIO-3000 motherboard
Relay Type:
Plugable fast acting reed
Relay Rating:
10 watts .5 amp maximum
Life:
100 million cycle
PKD-3
PEAK HOLD MODULE Description
The PKD-3 Module provides very fast response
to variations in data level and captures the highest peak that occurs
in a given monitor window. Unlike microprocessor controlled meters
that covert in digital readings at three samples per second and then
save the highest reading, the PKD-3 tracks continually and holds in
analog form until reset. The module has polarity select and reset control
which can be operated from the front edge of the module or remotely
by switching TTL control lines to ground.
A typical application for the PKD-3 is with a TMO-3 and a torque transducer
and used with an automatic nut runner. When the runner stalls, peak
torque is saved. If backoff torque is needed for system evaluation,
the module can be rest to zero and the polarity changed, both by computer.
MODULE
SPECIFICATIONS
Input Range:
0 to +- 5 VDC
Output Range:
0 to +- 5 VDC
Response Time:
Less than .5ms
Reset Time:
50 minimum
Droop:
Less than 2 mV/minute
Power:
From TIO-3000 motherboard
SUM-3
PRECISION SUMMING MODULE Description
The SUM-3 Module is designed for precise weighing application
by accepting the output signals from 2, 3 or 4 TMO-3 conditioning modules
and performing the algebraic sum of those signals. Unlike resistor
summers, the active element summing junction does not require sensor
signals of matching output. The TIO-3000 approach provides a cal resistor
to scale amplifiers (TMO-3s) to engineering units. With data now standard
during setup, precision summing is accomplished.
Advantages
1.
Load cells are less expensive if calibrated, not standardized.
2.
A damaged sensor can be replaced and the system rescaled to
the new sensorical resistor.
3.
Load cells of two different capacities can be summed.
4.
Load cells may be dispersed at uneven locations to weigh an
odd shaped tank or structure.
Options
A 4 to 20 mA current loop output
is available as Option "A".
MODULE
SPECIFICATIONS
Summing Accuracy:
+-.1% of inputs
Input Range (4 Inputs):
+-2.5% VDC
Output Range:
+-10 VDC
Stability:
.05% for 24 hours
Tempco:
.01% per [degree symbol]C
Power:
From TIO-3000 motherboard
Order
Code Model
Capacity
Range
Description
Price
Quantity
Add
to Cart
Home |
Products |
Tech Support |
About Us |
Contact Us