Print Load Cell Items and Accessories

MODEL DAQ-16162-FW

(NI DAQPad-6052E)

Features
  • Two 16-bit analog outputs, 8 digital
    I/O lines, two 24-bit counters
  • NI-DAQ driver software to simplify
    configuration and measurements
  • Four analog input signal ranges
  • NIST-traceable calibration certificate
  • Digital triggering

Model DAQ-16162-FW
Price
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG24 N/A 295.00
DAQ-DLS16 N/A 195.00
DP-16162-FW-DL N/A 3725.00
ADDITIONAL DUAL CHANNEL STRAIN GAUGE MODULES BELOW
DAQ-SCC-SG04 N/A 295.00
PACKAGE BELOW INCLUDES LabVIEW BASE PACKAGE SOFTWARE
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-BP N/A 995.00
DP-16162-FW-BP N/A 4525.00
PACKAGE BELOW INCLUDES LabVIEW FULL DEVELOPMENT SYSTEM SOFTWARE
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-FDS N/A 1995.00
DP-16162-FW-FD N/A 5525.00
Bus Analog
Inputs
Resolution Sampling
Rate S/s
Input
Range
Analog
Outputs
Resolution Output
Rate
Output
Range
Digital
I/O
Counter/
Timers
Triggers
FW 16 SE/8/DI 16 bits 333 kS/s ±.05
to ±10V
2 16 bits 333 kS/s ±10V 8 2, 24-bit Analog &
Digital
10 kS/s maximum when using the single ended DMA channel for for analog ouput. 1 kS/s maximum when using the single DMA channel for either analog input or counter / timer operation.
ANALOG INPUT ACCURACY SPECIFICATIONS
Nominal Range (V) Absolute Accuracy Relative Accuracy
% of
Reading
Offset
(mV)
Noise + Quantization (mV) Temp
Drift
(%/C)
Absolute Accuracy
at Full Scale (mV)
Resolution
(mV)
Positive
FS
Negative
FS
24 Hrs 1 year Single Pt. Averaged Single Pt. Averaged
10.0 -10.0 .035 .037 947 981 87 .00006 4.747 1145 115
5.0 -5.0 .005 .007 476 491 43.5 .00001 .876 573 57.3
2.5 -2.5 .035 .037 245 245 21.7 .00006 1.190 286 28.6
1.0 -1.0 .035 .037 99 98 8.7 .00006 .479 115 11.5
Note: Accuracies are valid measurements following internal calibration. Averaged numbers assume dithering and averaging of 100 single readings. Measurements accuracies are listed for operational temperatures within ± 1 degree C of internal calibration temperature and ± 10 degrees C of external or factory calibration temperature. One year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage, 10 (for example, 10V range for ± 10V range) after one year, assuming 100 pt averaging of data.
Price
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG24 N/A 295.00
DAQ-DLS16 N/A 195.00
DP-16162-FW-DL N/A 3725.00
ADDITIONAL DUAL CHANNEL STRAIN GAUGE MODULES BELOW
DAQ-SCC-SG04 N/A 295.00
PACKAGE BELOW INCLUDES LabVIEW BASE PACKAGE SOFTWARE
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-BP N/A 995.00
DP-16162-FW-BP N/A 4525.00
PACKAGE BELOW INCLUDES LabVIEW FULL DEVELOPMENT SYSTEM SOFTWARE
DAQ-16162-FW N/A 2895.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-FDS N/A 1995.00
DP-16162-FW-FD N/A 5525.00