Print Load Cell Items and Accessories

MODEL DAQ-16122-PCI

(NI PCI-6024E)

Features
  • Two 12-bit analog outputs, 8 digital
    I/O lines, two 24-bit counters
  • NI-DAQ driver software to simplify
    configuration and measurements
  • Four analog input signal ranges
  • NIST-traceable calibration certificate
  • Digital triggering

Model DAQ-16122-PCI
Price
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
DAQ-DLS16 N/A 195.00
DP-16122-PCI-DL N/A 1425.00
ADDITIONAL DUAL CHANNEL STRAIN GAUGE MODULES BELOW
DAQ-SCC-SG04 N/A 295.00
PACKAGE BELOW INCLUDES LabVIEW BASE PACKAGE SOFTWARE
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-BP N/A 995.00
DP-16122-PCI-BP N/A 2225.00
PACKAGE BELOW INCLUDES LabVIEW FULL DEVELOPMENT SYSTEM SOFTWARE
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-FDS N/A 1995.00
DP-16122-PCI-FD N/A 3225.00
Bus Analog
Inputs
Resolution Sampling
Rate S/s
Input
Range
Analog
Outputs
Resolution Output
Rate
Output
Range
Digital
I/O
Counter/
Timers
Triggers
PCMCIA 16 SE/8/DI 12 bits 200 kS/s ±.05
to ±10V
2 12 bits 10 kS/s ±10V 8 2, 24-bit Digital
10 kS/s maximum when using the single ended DMA channel for for analog ouput. 1 kS/s maximum when using the single DMA channel for either analog input or counter / timer operation.
ANALOG INPUT ACCURACY SPECIFICATIONS
Nominal Range (V) Absolute Accuracy Relative Accuracy
% of
Reading
Offset
(mV)
Noise + Quantization (mV) Temp
Drift
(%/C)
Absolute Accuracy
at Full Scale (mV)
Resolution
(mV)
Positive
FS
Negative
FS
24 Hrs 1 year Single Pt. Averaged Single Pt. Averaged
 10.0 -10.0 .0872 .0914 8.830 3.190 1.042 .0010 19.012 5.890 1.370
5.0 -5.0 .0272 .0314 4.420 1.950 .521 .0005 6.517 2.950 .686
.05 -.05 .0872 .0914 .462 .195 .052 .0010 .972 .516 .069
.05 -.05 .0872 .0914 .066 .063 .007 .0010 .119 .073 .009
valid measurements following internal calibration. Averaged numbers assume dithering and averaging of 100 single readings. Measurements accuracies are listed for operational temperatures within ± 1 degree C of internal calibration temperature and ± 10 degrees C of external or factory calibration temperature. One year calibration interval recommended. The Absolute Accuracy at Full Scale calculations were performed for a maximum range input voltage, 10 (for example, 10V range for ± 10V range) after one year, assuming 100 pt averaging of data.
Price
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
DAQ-DLS16 N/A 195.00
DP-16122-PCI-DL N/A 1425.00
ADDITIONAL DUAL CHANNEL STRAIN GAUGE MODULES BELOW
DAQ-SCC-SG04 N/A 295.00
PACKAGE BELOW INCLUDES LabVIEW BASE PACKAGE SOFTWARE
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-BP N/A 995.00
DP-16122-PCI-BP N/A 2225.00
PACKAGE BELOW INCLUDES LabVIEW FULL DEVELOPMENT SYSTEM SOFTWARE
DAQ-16122-PCI N/A 595.00
DAQ-CAB-PCI N/A 95.00
DAQ-SC-2345 N/A 245.00
DAQ-SCC-SG04 N/A 295.00
Lab-VIEW-FDS N/A 1995.00
DP-16122-PCI-FD N/A 3225.00