Print Load Cell Items
Made in the USA

MODEL DPM-2

The voltage-to-frequency microprocessor makes Transducer Technique's 4-digit panel mount meters the ideal solution for meeting the measurement, display and control requirements of noisy industrial applications, OEMs and system designers. Model DPM-2 accepts any full bridge transducer. Balance and span can be selected via the front keypad, thus allowing the display to read directly in engineering units. Front panel max and tare functions are ideal for industrial weighing applications. Isolated adjustable 9-11 VDC excitation with remote sense and 90 mA drive eliminates the need for external power supplies. Rear screw terminals connectors are included.

dpm-2 load cell display
Price
DPM-2 N/A 550.00
DPM-2-C N/A 660.00
DPM-2-CH N/A 880.00
DPM-2-CHT N/A 1030.00
DPM-2-H N/A 800.00
DPM-2-HT N/A 900.00
DPM-2-T N/A 690.00
FEATURES
  • Front panel tare function
  • Automatic storage of max reading
  • .5 inch intensity display
  • Security lockout code
  • Plug-in screw terminals
PLUG-IN OPTIONS
  • OPTION C is a dual setpoint controller 5 Amp, 125 VAC From C relays
  • OPTION H is an isolated linearized analog outputs
    0 to 10 VDC or 4-20 mA
  • OPTION T is an isolated digital communications
    RS 232 serial data output
Price
DPM-2 N/A 550.00
DPM-2-C N/A 660.00
DPM-2-CH N/A 880.00
DPM-2-CHT N/A 1030.00
DPM-2-H N/A 800.00
DPM-2-HT N/A 900.00
DPM-2-T N/A 690.00
Specifications

Display

Type 4 LED, 6 -segment, 13.0mm (.50%u201D)
Color Blue-Green
Range -9999 to +9999

A to D Conversion

Rate 4/s at 60 Hz operation
Output Update Rate 2/s at 60 Hz operation
Display Update Rate 2/s at 60 Hz operation

Accuracy at 25°C

Load Cell Meter 0.01% FS ± 1 Ct.
Span Tempco 0.008% of reading/°C
Zero Tempco 0.1 Cts./°C
Reference Junction 0.03 degree/degree

Noise Rejection

CMV from DC to 60 Hz 2500 V peak, input to power line with AC power supply
CMR from DC to 60 Hz 80 dB Typical
NMR to 50/60Hz line 60 dB Typical

Environmental

Operating Temperature 0°C to 45°C
Storage Temperature -40°C to +85°C
Relative Humidity 80% at 40°C, noncondensing

Operating Power

Voltage 115 VAC or 230 VAC

Excitation Supply

Outputs Adjustment range +9 VDC to + 11 VDC , 90 mA

Panel Cutout

Height 1.78
Length 3.63
Price
DPM-2 N/A 550.00
DPM-2-C N/A 660.00
DPM-2-CH N/A 880.00
DPM-2-CHT N/A 1030.00
DPM-2-H N/A 800.00
DPM-2-HT N/A 900.00
DPM-2-T N/A 690.00