Print Load Cell Items
Made in USA

GSO SERIES

CAPACITY RANGES:
10, 25, 30, 50, 100, 150,
250, 500, 1,000 GRAMS

The GSO Series strain gauge load cells can be utilized in tension or compression or both with excellent compliance. The force sensing end of the anodized aluminum GSO Series load cell is tapped 6-32 thru for attachment possibilities for almost any force measurement application. Bonded foil strain gauges at the sensing element provide for excellent stability over the suggested temperature range and ensure long term reliability. Call for application assistance.

GSO Series precision gram Load Cell

The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
GSO-10 10 grams 835.00
GSO-25 25 grams 835.00
GSO-30 30 grams 745.00
GSO-50 50 grams 745.00
GSO-100 100 grams 745.00
GSO-150 150 grams 745.00
GSO-250 250 grams 745.00
GSO-500 500 grams 745.00
GSO-1K 1000 grams 745.00
Options
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
Accessories
ALS-04 N/A 35.00
ALS-06 N/A 35.00
ALS-08 N/A 35.00
Specifications
Rated Output (R.O.): 1 mV/V nominal
Nonlinearity: 0.05% of R.O.
Hysteresis: 0.05% of R.O
Nonrepeatability: 0.05% of R.O.
Zero Balance: 3.0% of R.O.
Compensated Temp. Range: 60° to 160°F
Safe Temp. Range: -65° to 200°F
Temp. Effect on Output: 0.005% of Load/°F
Temp. Effect on Zero: 0.005% of R.O./°F
Terminal Resistance: 350 ohms nominal
Excitation Voltage: 10 VDC
Safe Overload: 150% of R.O.
Deflection Inches: 0.004 @ R.O.
Weight: 1 oz all ranges
Calibration Included: Compression
Optional Calibration: Tension
Dimensions in Inches, GSO-10 through 1000
gso series load cell specifications
Model Capacity Grams Natural Ringing
Frequency Hz
Deflection Inches
GSO-10 10 260 0.004
GSO-25 25 475 0.004
GSO-30 30 360 0.004
GSO-50 50 440 0.004
GSO-100 100 610 0.004
GSO-150 150 700 0.004
GSO-250 250 1000 0.004
GSO-500 500 1450 0.004
GSO-1K 1,000 2000 0.004
The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
GSO-10 10 grams 835.00
GSO-25 25 grams 835.00
GSO-30 30 grams 745.00
GSO-50 50 grams 745.00
GSO-100 100 grams 745.00
GSO-150 150 grams 745.00
GSO-250 250 grams 745.00
GSO-500 500 grams 745.00
GSO-1K 1000 grams 745.00
Options
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
Accessories
ALS-04 N/A 35.00
ALS-06 N/A 35.00
ALS-08 N/A 35.00
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
Wiring Color Code (WCC1) 4 Conductor

OPT-TEDS Plug & Play Option

AD9 (9 PIN "D" Series) Connector attached to the end of a Load Cell or Torque sensor cable with a TEDS (Transducer Electronic Data Sheet) EEPROM. Used with a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will self calibrate. This option is a real time saver. Read additional article...
cal-teds plug and play option
Smart Load Cell Plug and Play Systems
Learn about Plug & Play Smart Load Cell Systems.
DPM-3 Panel Mount Load Cell Display
DPM-3 Panel Mount Smart Load Cell Meter
Plug & Play Smart Digital
Panel Mount Load Cell Meter
IEEE 1451.4 Compliant
$570.00 to $625.00
»More info
SSI Portable Hand-Held Load Cell Indicator
SSI Portable Hand-Held Load Cell Indicator
Ultra-Fast 15 kHz Plug & Play Smart Hand Held
Indicator With Data Logging
IEEE 1451.4 Compliant
$950.00
»More info
SST Transmitter
SST-HV High Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
High Voltage 85-265 Vac
$475.00
»More info
SST Transmitter
SST-LV Low Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
Low Voltage 10-48 Vdc
$510.00
»More info
The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
GSO-10 10 grams 835.00
GSO-25 25 grams 835.00
GSO-30 30 grams 745.00
GSO-50 50 grams 745.00
GSO-100 100 grams 745.00
GSO-150 150 grams 745.00
GSO-250 250 grams 745.00
GSO-500 500 grams 745.00
GSO-1K 1000 grams 745.00
Options
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
Accessories
ALS-04 N/A 35.00
ALS-06 N/A 35.00
ALS-08 N/A 35.00
SSI Portable Hand-Held Load Cell Indicator
SSI Portable Hand-Held Load Cell Indicator
Ultra-Fast 15 kHz Plug & Play Smart Hand Held
Indicator With Data Logging
IEEE 1451.4 Compliant
$950.00
»More info
DPM-3 Panel Mount Load Cell Display
DPM-3 Panel Mount Smart Load Cell Meter
Plug & Play Smart Digital
Panel Mount Load Cell Meter
IEEE 1451.4 Compliant
$570.00 to $625.00
»More info
DPM-2 Load Cell Display
DPM-2 Load Cell Display
Panel Mount Meter
Amplifier / Conditioner
$550.00 to $1,030.00
»More info
TIO-3000 Load Cell Display
TIO-3000 Load Cell Display
Versatile 5-Channel Industrial
Amplifier / Conditioner
$1,550.00 to $1,725.00
»More info
SST Transmitter
SST-HV High Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
High Voltage 85-265 Vac
$475.00
»More info
SST Transmitter
SST-LV Low Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
Low Voltage 10-48 Vdc
$510.00
»More info
LCA Load Cell Amplifier Signal Conditioner Module with DB9 Connectors
LCA-9PC Load Cell Amplifier Signal Conditioner with DB9 Connectors
Low Cost 12 to 26 Vdc Powered
Bridge Sensitivity 0.5 mV/V to 10 mV/V
Selectable Filter 100 HZ to 30 kHZ
$425.00
»More info
LCA-RTC Load Cell Amplifier Signal Conditioner Module
LCA-RTC Load Cell Amplifier Signal Conditioner with Removable Terminals
Low Cost 12 to 26 Vdc Powered
Bridge Sensitivity 0.5 mV/V to 10 mV/V
Selectable Filter 100 HZ to 30 kHZ
$425.00
»More info
TMO-2 Load Cell Signal Conditioner
TMO-2 Load Cell Signal Conditioner
Stand Alone / Bench Top
Amplifier / Conditioner Module
0 to ±10 Vdc Output
$525.00
»More info
TMO-2A Load Cell Signal Conditioner
TMO-2A Load Cell Signal Conditioner
Stand Alone / Bench Top
Amplifier / Conditioner Module
4-20 mA Output
$585.00
»More info
PSM-R Load Cell Power Supply
PSM-R Load Cell Power Supply
4 To 15 Vdc Power Supply Module
$325.00
»More info
PSM-F10 Load Cell Power Supply
PSM-F10 Load Cell Power Supply
10 Vdc Fixed Power Supply Module
$320.00
»More info

What is a Load Cell?

A load cell is a force transducer — a sensor that turns mechanical force into a proportional electrical signal. That definition holds whether the sensor is measuring a hundred thousand pounds on a structural test frame or a single gram in a laboratory instrument. What changes dramatically across that range is how the sensor has to be designed, handled, and installed to deliver a trustworthy number.

The measuring principle is the same in both cases. Bonded foil strain gauges are attached to a machined flexure inside the load cell body and wired into a Wheatstone bridge circuit. Applied force deflects the flexure by a very small amount, the strain gauges deform with it, and their electrical resistance changes in proportion. The bridge converts those resistance changes into a millivolt-level output signal that tracks the applied force.

What makes a low capacity load cell a distinct engineering problem is the ratio between what you're trying to measure and everything else in the system. On a gram load cell, the mounting hardware, a length of cable, a fixture bracket, or a fingerprint's worth of debris can represent a meaningful fraction of full scale. The flexure has to be compliant enough to strain measurably under a gram or two of force, which leaves very little mechanical margin before an accidental bump becomes an overload. The output signal is small enough that cable routing, grounding, and excitation stability move from "good practice" to "the difference between usable and useless data."

Load cells are built in a range of configurations to suit different jobs. Compression designs are loaded along their axis and are common in weighing and platform applications. Tension designs are pulled and suit crane scales and tensile testing. Bending beam, shear beam, and single-point designs are workhorses in scales and batching systems. S-type cells handle both tension and compression. Through-hole and load washer designs allow a bolt or shaft to pass through the sensor. In the ultra low capacity and precision gram ranges, sensors are typically compact, low-deflection designs machined from anodized aluminum, sized to be integrated directly into an instrument or fixture.

Precision force sensors in the gram range show up wherever small forces carry high consequences: laboratory balances and analytical instruments, pharmaceutical dispensing and capsule filling, wire bonding and die bonding in semiconductor assembly, infusion and syringe pump verification, biomechanics research, micro-scale materials testing, and product development work on anything small enough that a conventional load cell would simply read zero.


How does a Load Cell work?

The chain from applied force to usable measurement has six links, and on a low capacity sensor every one of them deserves more attention than it would on a larger cell.

1. Strain in the flexure. Force applied to the load cell deflects an internal machined element. On precision gram-range sensors that deflection is measured in thousandths of an inch even at full rated load — small enough that it's effectively invisible, but enough to strain the gauges bonded to it.

2. Resistance change in the strain gauges. Strain gauges bonded to that flexure change electrical resistance as they deform: resistance rises when stretched and falls when compressed. The change is minute, which is precisely why a bridge circuit is used to detect it.

3. Bridge imbalance. The gauges are wired into a Wheatstone bridge, with gauges placed so that some go into tension and others into compression under the same applied load. Their opposing resistance changes unbalance the bridge and produce a differential output voltage that is proportional to the applied force. This arrangement also cancels much of the common-mode effect of temperature on the gauges themselves.

4. Excitation determines signal size. A load cell doesn't generate a signal on its own; it modulates the excitation voltage applied across the bridge. That's why sensitivity is specified in millivolts per volt (mV/V) — the output scales directly with excitation. A cell rated at 1 mV/V excited at 10 VDC produces about 10 mV at full capacity, and every bit of instability in that excitation shows up directly in the reading. Smaller, lower-capacity cells tend to be more sensitive to excitation behavior than large ones, which is one reason matching the excitation used during calibration to the excitation used in service matters.

5. Amplification and conditioning. A signal measured in single-digit millivolts has to be amplified and filtered before anything useful can be done with it. Lower-output sensors need proportionally more gain, and more gain amplifies noise along with signal — which is why shielded cable, sound grounding, and appropriate filtering matter so much at the low end of the capacity range.

6. Calibration ties it to reality. Known reference forces are applied and the corresponding outputs recorded, establishing the relationship between electrical output and engineering units. Note that this relationship is direction-specific: a cell calibrated in compression has a documented compression relationship, and tension performance is a separate calibration rather than an assumption.

The practical takeaway is that a precision gram load cell is a system, not just a part. The sensor's published nonlinearity and hysteresis figures describe what it can do under good conditions; unstable excitation, a noisy cable run, an unzeroed fixture, or a single overload event will dominate those specs long before the sensor's own limits become the constraint.


Load Cell Choices

Choosing a low capacity load cell follows the same logic as choosing any force sensor, but the margins are tighter and a few decisions carry more weight than they would at higher capacities. Here's how we'd walk through it with you.

Start with your real force range, then check the extremes. Identify the force you actually expect to measure most of the time — that's what should sit comfortably within the sensor's range so you get useful resolution. Then separately identify your realistic worst case, including setup, handling, and anything that could go wrong in the fixture. In the gram range those two numbers are often much closer to each other than people expect, and the gap between them is where sizing decisions get made. Offering capacities in fine steps exists precisely so you don't have to jump from 100 grams to 1,000 grams and give up resolution across the range you care about.

Decide the loading direction before you order. Will the sensor be pushed, pulled, or both? This matters more than it sounds, because calibration is direction-specific. If a sensor ships calibrated in compression and your application pulls, specify tension calibration at order time rather than discovering the gap after installation.

Think about deflection and frequency together. Lower-capacity sensors generally deflect more relative to their rated load and have lower natural frequencies than stiffer, higher-capacity ones. If your measurement is slow or static, that's a non-issue. If you're capturing something that changes quickly, natural frequency becomes a real constraint on how fast a signal you can trust, and it's worth discussing before you choose a capacity.

Plan the mounting before the purchase order. How will the sensor attach to your fixture, and how will load be introduced into it? Threaded mounts, adapters, and fixture geometry all need to deliver force along the sensor's measuring axis. Side loads and misalignment that a large load cell would shrug off can meaningfully corrupt a gram-level measurement, and mechanical hard stops or travel limits in the fixture are cheap insurance against overload.

Match the instrumentation to the output. A lower mV/V sensor produces a smaller signal, so your signal conditioner or amplifier and display need to be capable of resolving it cleanly. Confirm the instrument supports your sensor's sensitivity range and excitation requirement rather than assuming any conditioner will do. If you'll be moving a sensor between instruments or fixtures, our Cal-Teds plug and play option stores the calibration data on the load cell itself so a compatible display can configure itself automatically instead of requiring manual entry each time.

Account for the environment. Temperature is the quiet variable here. Compensated ranges define where published accuracy holds; outside that band, readings can drift even though nothing about the applied force has changed. Cleanroom, laboratory, and integrated-instrument environments each bring their own handling and cabling considerations.

Don't forget documentation and traceability. If the measurement supports quality control, regulatory work, or research you'll publish, decide early whether you need a calibration certificate, what recalibration interval your quality system requires, and whether data needs to be logged rather than just observed.

Precision at this scale is genuinely unforgiving, and there's no shame in getting a second opinion on sizing before committing. Send us your expected force range, worst case, mounting arrangement, and what the data is for, and we'll help you land on the right sensor and instrument combination. We stock standard products for next-day shipping and offer educational discounts for academic labs.


GSO Series Gram Load Cell Applications.

Gram load cells, also known as gram-scale load cells, are specialized sensors designed to measure extremely small forces or weights, typically in the range of grams (1 gram = 0.035 ounces). These load cells are used in a variety of applications where high precision and sensitivity are required. Here are some common applications where gram load cells are used:

  • Laboratory Balances: Gram load cells are commonly used in laboratory balances and scales for precise measurements of chemicals, samples, and materials. They provide accurate weight measurements for research, quality control, and analytical purposes.
  • Pharmaceutical Industry: In pharmaceutical manufacturing, gram load cells are employed for pill counting, powder dispensing, and capsule filling machines to ensure precise dosages and quality control.
  • Food Industry: In food processing and packaging, gram load cells are used in weighing systems to measure ingredients, portion control, and checkweighing applications. They help maintain product consistency and compliance with weight regulations.
  • Materials Testing: Gram load cells are used in materials testing machines to determine the mechanical properties of materials, such as tensile strength, compression, and flexural modulus. These load cells provide accurate data for research and quality control in materials engineering.
  • Microelectronics Manufacturing: In the microelectronics industry, gram load cells are used for die bonding, wire bonding, and other assembly processes that require precise force control. They ensure the accurate placement of tiny components on semiconductor wafers.
  • Medical Devices: Gram load cells play a crucial role in medical devices, such as infusion pumps, syringe pumps, and blood analyzers. They help deliver precise medication dosages and ensure accurate test results.
  • Aerospace and Aviation: In the aerospace industry, gram load cells are used for applications such as the testing of small aircraft components, including sensors, actuators, and control systems, where precise force measurements are critical for safety and performance.
  • Automotive Manufacturing: In the automotive industry, gram load cells are used for quality control and testing of small components, such as fuel injectors, valves, and switches. They help ensure the reliability and performance of automotive parts.
  • Packaging Machinery: Gram load cells are integrated into packaging machines to monitor and control the filling and sealing of small packages, ensuring accurate and consistent packaging of products.
  • Research and Development: In various research and development fields, gram load cells are used for specialized experiments and testing where the measurement of small forces or weights is essential. This includes applications in physics, chemistry, and material science.
  • Biotechnology: In biotechnology and life sciences, gram load cells are employed in equipment for sample preparation, DNA sequencing, and other applications requiring precise measurements of biological materials.
  • Jewelry and Precious Metals: Gram load cells are used in jewelry scales and precious metal analysis equipment to measure the weight and purity of precious metals accurately.

In all these applications, gram load cells enable high-precision measurements, quality control, and process optimization, making them essential components in various industries where accuracy is paramount.

Frequently Asked Questions

What is the GSO series, and what capacity range does it cover?

The GSO series is our precision gram-force load cell line, built to measure very small tension or compression loads with excellent compliance. It's available in nine capacities — 10, 25, 30, 50, 100, 150, 250, 500, and 1,000 grams — so you can match the sensor's full-scale range closely to your expected force rather than using an oversized cell that sacrifices resolution at the low end.

Why is the GSO series calibrated in compression by default, and can it still be used in tension?

The GSO ships with a default calibration in compression, which covers the majority of gram-scale weighing and force-testing applications. If your application requires tension measurement, an optional tension calibration is available as an upgrade — worth specifying at order time if you know your application will be pulling rather than pushing, since it establishes the tension calibration curve specifically rather than assuming compression performance carries over unchanged.

What output sensitivity and excitation voltage does the GSO series use?

The GSO series has a rated output of 1 mV/V nominal and a terminal (bridge) resistance of 350 ohms, and it's excited at 10 VDC. Because the rated output is relatively low compared to some higher-mV/V load cells, your signal conditioner or display needs to be capable of accurately amplifying that smaller signal — confirm your instrumentation supports a 1 mV/V-range input before pairing it with a GSO cell.

How accurate is the GSO series?

The GSO is specified at 0.05% of rated output for both nonlinearity and hysteresis, with a zero balance of 3.0% of rated output. Those figures make it well suited to precision, repeatable gram-level measurement, though as with any precision instrument, accuracy in practice also depends on proper mounting, stable excitation, and periodic calibration.

What is the safe overload rating on a GSO load cell, and what happens if I exceed it?

The GSO series has a safe overload rating of 150% of rated capacity. Loading beyond that limit risks a permanent zero shift, degraded accuracy, or physical damage to the sensing element — and because these are gram-range cells with very little mechanical margin to begin with, it's worth being especially deliberate about fixturing and handling to avoid accidental overload during setup or testing.

How is a GSO load cell mounted, and what connection does it use?

The GSO series uses a tapped 6-32 threaded connection, machined into an anodized aluminum body, giving you a straightforward, versatile mounting point for fixtures, hooks, or platens without needing a separate mounting adapter in most setups.

Why does natural frequency vary across the GSO series' different capacities?

Natural frequency response on the GSO series ranges from roughly 260 Hz on the smallest capacity (GSO-10) up to about 2,000 Hz on the largest (GSO-1K), increasing as capacity goes up. This follows a general rule with strain-gauge load cells: lower-capacity cells need to deflect more to produce a usable signal at their much smaller rated load, and more deflection generally means a lower natural frequency and slower response to fast-changing forces.

What is the TEDS/Plug & Play option on the GSO series, and is it worth adding?

The GSO series offers an optional Plug & Play TEDS connector, which lets a compatible TEDS-equipped display or conditioner automatically read the load cell's calibration data and configure itself, rather than requiring manual calibration entry. It's a worthwhile add if you expect to swap this load cell between fixtures or instruments regularly; for a cell that will stay permanently wired into one system, it's more of a convenience than a necessity.

What temperature range can a GSO load cell operate in?

The GSO series is temperature-compensated from 60°F to 160°F, meaning accuracy is maintained within that band, with a safe (non-damaging) operating range extending from -65°F to 200°F. Operating outside the compensated range won't necessarily harm the sensor, but readings may drift until it's back within the compensated window.

What is the deflection on a GSO load cell at rated output, and why does that matter for a gram-force sensor?

The GSO series deflects just 0.004 inches at rated output across all capacities. That small, consistent deflection is part of what allows a sensor this sensitive to measure gram-level forces accurately, but it also means there's very little physical give in the sensing element — reinforcing why precise, low-side-load mounting and careful handling matter more on a gram-range cell than on a larger, higher-capacity load cell.

Questions From The Field

My GSO load cell was calibrated in compression — can I use it for tension without recalibrating?

Not reliably. The default GSO calibration establishes an accurate force-to-signal relationship specifically for compression loading, and that relationship isn't guaranteed to carry over precisely to tension. If your application needs tension measurements, order (or send the unit back for) the optional tension calibration rather than assuming the compression calibration will hold in the opposite direction.

Can I run my GSO load cell at a lower excitation voltage than the rated 10 VDC?

Our GSO series is rated at 10 VDC excitation, but it's worth knowing that, industry-wide, smaller and lower-capacity load cells tend to be more sensitive to excitation voltage than larger ones, and some instrumentation setups run small cells at a lower excitation, such as 5V, for improved stability. If you're seeing instability and want to explore a different excitation level, check with us first — any deviation from the rated excitation should be matched consistently across your calibration and your measurement instrument, since a mismatch between the two is a common source of error.

Can I add the TEDS/Plug & Play option to a GSO load cell after I've already purchased it?

The Plug & Play TEDS connector is an option specified at the time of order, since it involves the connector and onboard memory chip built into the load cell itself. If you didn't order it originally and want to add it later, contact our support team — depending on the unit, it may be possible to send it back for the upgrade, but it isn't a field-installable modification.

Does the GSO-10's lower frequency response limit what kind of testing I can do with it compared to the GSO-1K?

It can, if your test involves fast-changing or dynamic forces. The GSO-10's roughly 260 Hz natural frequency means it responds more slowly to rapid force changes than the GSO-1K's roughly 2,000 Hz response, so a very fast dynamic event captured well by a GSO-1K might be under-reported or smoothed out on a GSO-10. For slow, steady, or static gram-level measurements this generally isn't a concern — it mainly matters if your application involves quick force transients at the low end of the capacity range.

My GSO reading shows a noticeable offset with no load applied — is that normal?

Some zero offset is expected and accounted for in the spec — the GSO's zero balance is rated up to 3.0% of rated output, which your instrumentation should be able to zero out during setup. If the offset is larger than that, is drifting over time, or won't zero out consistently, check your excitation stability and cabling first, and consider whether the cell may have seen an overload event that shifted its zero point.

Does the orientation I mount my GSO load cell in affect the reading?

At gram-level capacities, the load cell's own mounting hardware, cabling, and any attached fixture can represent a meaningful fraction of the rated load, so orientation and how you zero the system matter more than they would on a larger cell. Zero the system in the same orientation and configuration you'll actually be testing in, so any fixture weight or hardware is zeroed out rather than being read as part of your measured force.

How much torque should I use when mounting a GSO load cell into its 6-32 threaded connection?

Transducer Techniques doesn't publish a single torque figure for the GSO's 6-32 mount, so use a light, consistent hand-tightened fit rather than a wrench, and avoid overtightening — a gram-range cell has very little mechanical margin, and excessive mounting torque can preload or damage the sensing element before you've even applied a test force. If you have a specific fixture or high-repeatability application in mind, reach out to us and we can advise on mounting practice for your setup.

Since the GSO's safe overload is only 150% of capacity, how do I protect it from accidental overload during setup?

Because gram-range capacities leave very little headroom, it's worth building in mechanical safeguards where practical — such as a hard stop or travel limit on your fixture — rather than relying solely on careful technique. When first setting up a new test or fixture, it also helps to approach the expected load gradually and monitor the reading rather than applying full force immediately, so an unexpectedly high force can be caught before it exceeds the 150% limit.