Print Load Cell Items
Made in USA

MLP SERIES

CAPACITY RANGES:
10, 25, 50, 75, 100, 150, 200,
300, 500, 750, 1,000 lb

The model MLP Series load cells were designed with economy as first priority. They are a scaled down version of our successful LPO Series Load Cells. MLP-10 through MLP-300 are anodized aluminum. The MLP-25SS, MLP-200SS, MLP-300SS, and MLP-500 through MLP-1K are made from 17-4ph heat treated stainless steel. The unique low profile design of the MLP Series provides excellent stability for in line force measurement applications for tension and/or compression, while saving space at the same time.

MLP Series mini low profile Load Cell
OPTIONS
CO Mini Connector System, male
and female with 10' 4 cond.
color coded shielded cable
DB Dual Bridge

The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
MLP-10 10 lb 410.00
MLP-25SS 25 lb 540.00
MLP-25 25 lb 410.00
MLP-50 50 lb 410.00
MLP-75 75 lb 410.00
MLP-100 100 lb 410.00
MLP-150 150 lb 420.00
MLP-200SS 200 lb 550.00
MLP-200 200 lb 420.00
MLP-300SS 300 lb 550.00
MLP-300 300 lb 420.00
MLP-500 500 lb 550.00
MLP-750 750 lb 550.00
MLP-1K 1,000 lb 550.00
Options
Option-CO N/A 105.00
Option-DB N/A 575.00
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
Specifications
Rated Output (R.O.): 2 mV/V nominal
Nonlinearity: 0.1% of R.O.
Hysteresis: 0.1% of R.O
Nonrepeatability: 0.05% of R.O.
Zero Balance: 1.0% of R.O.
Compensated Temp. Range: 60° to 160°F
Safe Temp. Range: -65° to 200°F
Temp. Effect on Output: 0.005% of Load/°F
Temp. Effect on Zero: 0.005% of R.O./°F
Terminal Resistance: 350 ohms nominal
Excitation Voltage: 10 VDC
Safe Overload: 150% of R.O.
Calibration Included: Compression
Optional Calibration: Tension
mlp series load cell specifications
Dimensions in Inches
Model Capacity
lb
L L1 W W1 H Thread Thread Depth Natural Ringing
Frequency HZ
Deflection
Inches
wt.
oz
MLP-10 10 1.504 .600 .54 .375 .750 10-32 .200 2,175 .003 0.5
MLP-25SS 25 1.504 .600 .54 .375 .750 10-32 .200 2,175 .003 1.4
MLP-25 25 1.521 .600 .66 .500 .750 1/4-28 .230 2,200 .003 0.7
MLP-50 50 1.584 .625 .66 .500 .750 1/4-28 .230 2,500 .003 0.7
MLP-75 75 1.640 .650 .66 .500 .750 1/4-28 .230 2,800 .003 0.8
MLP-100 100 1.664 .660 .66 .500 .750 1/4-28 .230 4,500 .003 0.8
MLP-150 150 1.642 .575 .93 .750 1.00 3/8-24 .375 4,500 .003 1.3
MLP-200SS 200 1.640 .650 .66 .500 .750 1/4-28 .230 5,200 .003 2.0
MLP-200 200 1.688 .580 .93 .750 1.00 3/8-24 .375 5,200 .003 1.4
MLP-300SS 300 1.664 .660 .66 .500 .750 1/4-28 .230 5,200 .003 2.0
MLP-300 300 1.748 .600 .93 .750 1.00 3/8-24 .375 5,200 .003 3.0
MLP-500 500 1.658 .580 .93 .735 1.00 3/8-24 .375 5,200 .003 3.0
MLP-750 750 1.734 .585 .93 .735 1.00 3/8-24 .375 5,200 .003 3.0
MLP-1K 1,000 1.784 .615 .93 .735 1.00 3/8-24 .375 5,200 .003 3.0
The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
MLP-10 10 lb 410.00
MLP-25SS 25 lb 540.00
MLP-25 25 lb 410.00
MLP-50 50 lb 410.00
MLP-75 75 lb 410.00
MLP-100 100 lb 410.00
MLP-150 150 lb 420.00
MLP-200SS 200 lb 550.00
MLP-200 200 lb 420.00
MLP-300SS 300 lb 550.00
MLP-300 300 lb 420.00
MLP-500 500 lb 550.00
MLP-750 750 lb 550.00
MLP-1K 1,000 lb 550.00
Options
Option-CO N/A 105.00
Option-DB N/A 575.00
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
Wiring Color Code (WCC1) 4 Conductor

OPT-TEDS Plug & Play Option

AD9 (9 PIN "D" Series) Connector attached to the end of a Load Cell or Torque sensor cable with a TEDS (Transducer Electronic Data Sheet) EEPROM. Used with a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will self calibrate. This option is a real time saver. Read additional article...
cal-teds plug and play option
Smart Load Cell Plug and Play Systems
Learn about Plug & Play Smart Load Cell Systems.
DPM-3 Panel Mount Load Cell Display
DPM-3 Panel Mount Smart Load Cell Meter
Plug & Play Smart Digital
Panel Mount Load Cell Meter
IEEE 1451.4 Compliant
$570.00 to $625.00
»More info
SSI Portable Hand-Held Load Cell Indicator
SSI Portable Hand-Held Load Cell Indicator
Ultra-Fast 15 kHz Plug & Play Smart Hand Held
Indicator With Data Logging
IEEE 1451.4 Compliant
$950.00
»More info
SST Transmitter
SST-HV High Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
High Voltage 85-265 Vac
$475.00
»More info
SST Transmitter
SST-LV Low Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
Low Voltage 10-48 Vdc
$510.00
»More info
The Load Cells below come Calibrated in Compression, Tension Calibration is optional
Price
MLP-10 10 lb 410.00
MLP-25SS 25 lb 540.00
MLP-25 25 lb 410.00
MLP-50 50 lb 410.00
MLP-75 75 lb 410.00
MLP-100 100 lb 410.00
MLP-150 150 lb 420.00
MLP-200SS 200 lb 550.00
MLP-200 200 lb 420.00
MLP-300SS 300 lb 550.00
MLP-300 300 lb 420.00
MLP-500 500 lb 550.00
MLP-750 750 lb 550.00
MLP-1K 1,000 lb 550.00
Options
Option-CO N/A 105.00
Option-DB N/A 575.00
OPT-TEDS N/A 115.00
TC-CAL N/A 125.00
SSI Portable Hand-Held Load Cell Indicator
SSI Portable Hand-Held Load Cell Indicator
Ultra-Fast 15 kHz Plug & Play Smart Hand Held
Indicator With Data Logging
IEEE 1451.4 Compliant
$950.00
»More info
DPM-3 Panel Mount Load Cell Display
DPM-3 Panel Mount Smart Load Cell Meter
Plug & Play Smart Digital
Panel Mount Load Cell Meter
IEEE 1451.4 Compliant
$570.00 to $625.00
»More info
DPM-2 Load Cell Display
DPM-2 Load Cell Display
Panel Mount Meter
Amplifier / Conditioner
$550.00 to $1,030.00
»More info
TIO-3000 Load Cell Display
TIO-3000 Load Cell Display
Versatile 5-Channel Industrial
Amplifier / Conditioner
$1,550.00 to $1,725.00
»More info
SST Transmitter
SST-HV High Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
High Voltage 85-265 Vac
$475.00
»More info
SST Transmitter
SST-LV Low Voltage Load Cell Transmitter
Plug & Play Smart Load Cell Transmitter
IEEE 1451.4 Compliant
Low Voltage 10-48 Vdc
$510.00
»More info
LCA Load Cell Amplifier Signal Conditioner Module with DB9 Connectors
LCA-9PC Load Cell Amplifier Signal Conditioner with DB9 Connectors
Low Cost 12 to 26 Vdc Powered
Bridge Sensitivity 0.5 mV/V to 10 mV/V
Selectable Filter 100 HZ to 30 kHZ
$425.00
»More info
LCA-RTC Load Cell Amplifier Signal Conditioner Module
LCA-RTC Load Cell Amplifier Signal Conditioner with Removable Terminals
Low Cost 12 to 26 Vdc Powered
Bridge Sensitivity 0.5 mV/V to 10 mV/V
Selectable Filter 100 HZ to 30 kHZ
$425.00
»More info
TMO-2 Load Cell Signal Conditioner
TMO-2 Load Cell Signal Conditioner
Stand Alone / Bench Top
Amplifier / Conditioner Module
0 to ±10 Vdc Output
$525.00
»More info
TMO-2A Load Cell Signal Conditioner
TMO-2A Load Cell Signal Conditioner
Stand Alone / Bench Top
Amplifier / Conditioner Module
4-20 mA Output
$585.00
»More info
PSM-R Load Cell Power Supply
PSM-R Load Cell Power Supply
4 To 15 Vdc Power Supply Module
$325.00
»More info
PSM-F10 Load Cell Power Supply
PSM-F10 Load Cell Power Supply
10 Vdc Fixed Power Supply Module
$320.00
»More info

What is a Load Cell?

The simplest way to think about a load cell is as an extremely stiff, extremely well-instrumented spring. Apply force and it deflects — not much, usually only a few thousandths of an inch, but measurably and predictably. Strain gauges bonded to the deflecting element turn that tiny movement into an electrical signal, and because the deflection is proportional to the applied force, so is the signal.

That framing explains most of what separates one load cell design from another. A sensor that deflects more produces a larger signal and is easier to read accurately at low forces, but it also responds more slowly to rapidly changing loads. A stiffer sensor gives up some of that signal but tracks fast events far better. Designers trade these against each other constantly, and the resulting deflection figure on a spec sheet tells you a great deal about what a given load cell is really for.

Inside, the mechanism is consistent across the industry. Four bonded foil strain gauges are attached to a machined flexure and wired into a Wheatstone bridge circuit. Under load, gauges on surfaces going into tension increase in resistance while those in compression decrease, unbalancing the bridge and producing a millivolt-level output proportional to the applied force. Nothing about that arrangement changes between a gram-range sensor and one rated for tens of thousands of pounds; what changes is the geometry and material of the flexure carrying the gauges.

Where a miniature load cell earns its keep is in the combination of a small physical envelope with real measurement performance. Packing a stiff, well-behaved flexure into a package weighing an ounce or two, with mounting threads on both ends and enough overload margin to survive an accident, is a harder engineering problem than it sounds — and it's why a miniature inline load cell tends to cost more per pound of capacity than a large industrial cell.

Common configurations across the category include compression-only designs, tension-only designs, universal tension and compression cells that handle both directions, S-beam designs for in-line push and pull, bending and shear beam designs used in scales and conveyors, low profile and pancake designs where vertical space is limited, and through-hole or load washer designs that let a bolt or shaft pass through the sensor. Miniature and low profile load cells in particular show up wherever a full-size sensor simply won't fit: test fixtures, robotic end-effectors, vehicle instrumentation, medical devices, and semiconductor assembly equipment.


How does a Load Cell work?

The electrical side of a load cell is straightforward. The mechanical side is where measurements actually go wrong, so it's worth understanding both.

The electrical chain. An excitation voltage — commonly 10 VDC — is applied across the Wheatstone bridge. Applied force strains the flexure, the bonded gauges change resistance, and the bridge produces a differential output measured in millivolts. Sensitivity is expressed in mV/V because output scales with excitation: a 2 mV/V sensor at 10 VDC delivers roughly 20 mV at full capacity. That signal is amplified, filtered, digitized, and scaled through the sensor's calibration into engineering units.

The mechanical chain is the harder one. A load cell measures force along one axis. Everything else it experiences — bending moments, torsion, side loads, thermal expansion in the fixture — is error it cannot distinguish from real signal. These off-axis forces are called extraneous loads, and they are the single most common reason a correctly specified sensor delivers disappointing data in the field.

Side loading happens when force arrives perpendicular to the measuring axis rather than along it, usually because the load string isn't aligned or the mounting plates aren't flat and parallel. In compression especially, a lateral component can push the flexure away from the intended load path, compounding the error and in severe cases threatening the sensor mechanically. Load cells have a documented tolerance for combined extraneous loads, and the practical rules are to align the load string carefully, keep loading surfaces flat and parallel, use couplings that absorb small misalignments rather than transmitting them, and inspect fixturing periodically rather than assuming it stayed square.

Speed changes the problem. Every load cell has a natural or ringing frequency — the rate at which its flexure oscillates when struck by a sudden force. Stiffer, lower-deflection designs ring higher and track fast events better. A widely applied rule of thumb is to keep the frequency content of what you're measuring to roughly one-fifth to one-tenth of the sensor's natural frequency; beyond that, output distorts in both amplitude and phase, and sharp impacts appear in the data as a decaying oscillation riding on the real signal.

Dynamic loading also changes how you size. A force that cycles, reverses, or arrives suddenly imposes peaks well above its nominal value, and repeated cycling is fatigue loading rather than simple static loading. A common approach in dynamic applications is to specify roughly double the capacity you would choose for the same force applied statically — you give up some resolution and buy back a great deal of margin and reliability.

Calibration closes the loop. Known reference forces are applied and the corresponding outputs recorded, establishing the force-to-signal relationship. Because the load path differs between pushing and pulling, compression and tension calibrations are separate operations, which is why tension calibration is typically a specified option rather than something assumed to come along with a compression calibration.


Load Cell Choices

Picking the right miniature load cell is mostly a matter of being honest about four things: how much force, how fast, how cleanly it arrives, and how little room you have. Our application engineers work through this every day, so if any of it is unclear for your setup, a phone call will save you time.

A real example of how this plays out. The Cornell racing team needed real-time force data from a race car suspension while the car was running on an actual track — about as unforgiving a set of conditions as force measurement gets. The loading was dynamic, the sensor would see extraneous loads it couldn't avoid, and the package had to be small enough to live in a suspension. We specified an MLP series load cell at double the nominal required capacity, which is our standard rule of thumb for dynamic loading, and it still exceeded the accuracy they needed. An LCA-RTC amplifier signal conditioner module fed high-speed data into their onboard acquisition system, and we designed a custom load pin alongside it to measure drivetrain torque. Sometimes a custom sensor is genuinely the right answer, and we'd rather tell you that than sell you a standard product that won't do the job.

Here's what to work through for your own application:

Force range, sized for how the load actually arrives. Start with the force you expect to measure most of the time so you get useful resolution. Then look hard at your worst case. If loading is static and well controlled, you can size fairly tight to your working range. If it's dynamic, cycling, or subject to sudden application, build in real margin — roughly double is a sensible starting point — and check that figure against the sensor's safe overload rating.

Direction and calibration. Tension, compression, or both? A universal cell handles both directions through one sensing element, but remember that calibration is direction-specific, so specify tension calibration at order time if your application pulls.

Speed and stiffness. If you're capturing anything faster than a slow, deliberate load, natural frequency becomes a real constraint rather than a footnote. Lower-deflection, stiffer designs ring higher and give you more usable measurement bandwidth. Tell us the fastest event you need to resolve and we can work backward to a suitable sensor.

Extraneous loads and mounting. This deserves as much thought as the sensor itself. How will force enter the cell, and can you guarantee it arrives along the measuring axis? Which thread size or mounting interface fits your fixture? Would a coupling that absorbs small misalignments protect your data? Misalignment ruins more measurements than any specification on the datasheet.

Environment and material. Anodized aluminum is light and well suited to a compact package at lower capacities. Precipitation-hardening stainless such as 17-4 PH offers substantially higher strength and better corrosion resistance, which is why it appears on higher-capacity and stainless variants. For sustained outdoor, marine, or submerged service, ask about a hermetically sealed cell rather than relying on material choice alone.

Redundancy and criticality. If a measurement failure would be expensive or unsafe — flight hardware, structural testing, anything you can't easily re-run — a dual bridge sensor gives you two independent outputs from one cell, so a fault in one channel doesn't cost you the test.

Options and instrumentation. Connector and cable configuration, plug-and-play Cal-Teds if you'll move the sensor between instruments, and the readout side: a precision power supply, an amplifier signal conditioner module, or a digital display with alarms, analog output, or data logging.

Standard products ship next day from stock, and educational discounts are available for academic labs. Send us your force range, how fast it changes, your available space, and how the sensor will mount, and we'll help you get from selection through installation.


MLP Series Load Cell Applications.

The Transducer Techniques MLP Series load cell is a miniature, universal tension and compression force measurement device with ten different capacities ranging from 0 to 10 lbs. to 0 to 100 lbs. and a full-scale deflection of 0.003 inches. Due to its compact size and high precision, the MLP Series load cell finds applications in a wide range of industries and scenarios where precise force measurement is essential. Here are some specific applications for the MLP Series load cell:

  • Microelectronics and Semiconductor Manufacturing: The MLP Series load cell is ideal for use in semiconductor manufacturing equipment for measuring and controlling forces during processes like die bonding, wire bonding, and wafer handling, ensuring the accuracy and reliability of microelectronic components.
  • Biomechanics Research: Researchers in biomechanics use MLP Series load cells to measure and analyze forces exerted on the human body during various activities. This data is crucial for understanding human movement and optimizing the design of orthopedic devices and sports equipment.
  • Medical Device Testing: In the medical device industry, MLP Series load cells are used for testing medical equipment and devices such as infusion pumps, catheters, and surgical instruments to ensure they meet force and performance specifications.
  • Automotive Component Testing: These load cells find applications in the automotive industry for testing components like switches, buttons, pedals, and airbag deployment systems to verify their functionality and safety.
  • Product Testing and Quality Control: MLP Series load cells are employed in quality control processes to verify the force requirements of manufactured products, ensuring that they meet quality and safety standards.
  • Material Testing: The MLP Series is suitable for materials testing applications, including tensile and compression testing of small-scale samples, enabling researchers and engineers to assess material properties with precision.
  • Aerospace and Aviation: These load cells are used in aerospace applications for measuring forces in small components, such as actuators and control surfaces, during testing and research to enhance the safety and performance of aircraft and spacecraft.
  • Custom Machinery: Manufacturers and research facilities incorporate MLP Series load cells into custom-built machinery and equipment for specialized testing and manufacturing processes that demand precise force measurement and control.
  • Educational Laboratories: Educational institutions utilize MLP Series load cells in physics and engineering laboratories to teach students about force measurement principles and conduct experiments related to mechanics and materials science.
  • Small-Scale Manufacturing: Industries like jewelry making and watch manufacturing use these load cells to ensure the precise assembly of small components and products.
  • Customized Force Measurement: MLP Series load cells can be adapted and customized for specific applications and industries where miniature force measurement is required, such as in the development of specialized sensors and research equipment.

The MLP Series load cell's compact size, high precision, and versatility make it an invaluable tool in industries that demand accurate force measurement in small-scale or precision applications.

Frequently Asked Questions

What capacities is the MLP Series available in?

The MLP Series spans eleven capacities: 10, 25, 50, 75, 100, 150, 200, 300, 500, 750, and 1,000 lb. That's an unusually wide range for a miniature load cell line, which means you can standardize on one sensor family across quite different test setups rather than mixing series as your force requirements change.

Why is the MLP's deflection the same 0.003 inches on every capacity?

Holding deflection constant across the range is a deliberate design choice, and it's one of the more useful things about this series. It means a 1,000 lb MLP moves no further under full load than a 10 lb MLP does under its own full load, so fixture design, clearances, and mechanical behavior stay predictable if you change capacity partway through a project. Many load cell families let deflection grow with capacity; keeping it fixed at 0.003 inches makes the MLP notably stiff for its size and keeps its dynamic behavior consistent across the line.

What makes the MLP Series suited to dynamic force measurement?

Stiffness. Natural frequency across the MLP range runs from about 2,175 Hz to 5,200 Hz, which is high for a sensor this size and a direct consequence of that low 0.003-inch deflection. A stiffer flexure oscillates faster and settles sooner, so it tracks rapidly changing forces with less distortion than a more compliant sensor would. That's why this series turns up in vehicle instrumentation, actuator testing, and other work where the force isn't sitting still.

What are the MLP Series' accuracy specifications?

Nonlinearity and hysteresis are each specified at 0.1% of rated output, nonrepeatability at 0.05% of rated output, and zero balance at 1.0% of rated output. Worth reading those together rather than in isolation: the tight nonrepeatability figure means the MLP returns very consistent readings when the same load is reapplied, which is usually what matters most in production testing and repeated-cycle work, even though its linearity spec is looser than some lower-capacity precision series.

What is the Option-DB dual bridge, and when would I need it?

Option-DB puts two independent strain gauge bridges inside a single MLP load cell, giving you two separate output signals from one sensor. The point is redundancy: if one channel develops a fault, the other keeps measuring, and during normal operation you can compare the two outputs as a live confidence check on your data. It's worth specifying when a measurement failure would be genuinely costly — flight or structural test hardware, a test that can't easily be repeated, or any application where you'd otherwise be tempted to install two separate sensors and have no room to do it.

Which MLP models are stainless steel, and what is 17-4 PH?

MLP-10 through MLP-300 are machined from anodized aluminum; the SS variants and the higher capacities use 17-4 PH stainless steel. 17-4 PH is a precipitation-hardening stainless, meaning it's heat treated so that fine particles form within the metal structure and dramatically raise its strength without the distortion that would ruin a precision part. The result is a material several times stronger than standard 304 stainless with good corrosion resistance in industrial environments — which is exactly what a compact, high-capacity sensing element needs.

What mounting threads does the MLP Series use?

Depending on the model, MLP load cells use 10-32, 1/4-28, or 3/8-24 threads, with the larger threads on the higher-capacity units. Check the thread size for your specific capacity before designing your fixture — because thread size steps up with capacity, a fixture built around one MLP model won't necessarily accept a different capacity from the same series without an adapter.

What is Option-CO, and do I need it?

Option-CO adds a mini connector system with a 10-foot cable, replacing a permanently attached lead with a connectorized one. It's worth adding if you'll be disconnecting the sensor regularly, routing it through a fixture or bulkhead, or swapping cells between test setups; if the load cell is going to be installed once and left alone, the standard configuration is usually all you need.

Is the MLP calibrated for tension, compression, or both?

The MLP is a universal design that measures in both directions mechanically, and it ships with compression calibration as standard. Tension calibration is available as the TC-CAL option. If your application pulls rather than pushes, or does both, specify tension calibration at order time so you have a documented calibration for the direction you're actually measuring in.

How much does the MLP weigh, and why does it vary?

MLP load cells range from about 0.5 to 3.0 ounces depending on capacity and material, with the lightest at the low-capacity aluminum end and the heaviest among the higher-capacity stainless models. That weight range matters more than it might seem in dynamic applications: added mass on a moving assembly changes the system's own dynamics, so if the sensor is mounted on something that accelerates, its mass belongs in your calculations.

Questions From The Field

How should I size an MLP if my loading is dynamic rather than steady?

Our general rule of thumb is to specify roughly double the capacity you'd choose for the same force applied statically. Dynamic loading produces transient peaks well above the nominal force, and repeated cycling is a fatigue problem rather than a simple static one, so that extra margin buys real reliability. You give up some resolution in exchange, but on a series like the MLP with consistently high natural frequency across the range, moving up a capacity step costs you less dynamically than it would on a more compliant sensor.

My MLP reads accurately on the bench but not in my fixture — what changed?

Almost always the answer is extraneous loading. A load cell measures along one axis only, and any bending moment, torsion, or side force your fixture introduces gets added to the reading with no way for the sensor to separate it out. Check that the load string is aligned with the sensor's axis, that any loading surfaces are flat and parallel, and that nothing in the fixture flexes or shifts as load is applied. A coupling that absorbs small misalignments, rather than a rigid connection that transmits them straight into the cell, often fixes this outright.

How much side load can an MLP tolerate before my data is compromised?

Load cells carry a documented allowable limit for combined extraneous loads, and the practical guidance is that all off-axis loads added together should stay within that limit — it's a combined budget, not a separate allowance for each type. Because that figure is model-specific, check the specification for your particular MLP capacity rather than assuming a general number. If your setup can't guarantee clean axial loading, tell us about the geometry and we can advise on couplings or an alternative approach.

Can I read both outputs of an Option-DB dual bridge MLP at the same time, on separate instruments?

That's the intended use — the two bridges are independent, so each can be wired to its own conditioner or acquisition channel and read simultaneously. Running them into separate instruments is what gives you genuine redundancy, since a failure in one signal chain then has no effect on the other. Each bridge needs its own excitation and its own calibration applied at the instrument, so plan your instrumentation for two channels rather than expecting one display to handle both.

Should I choose an MLP or an MDB for my application?

Both are miniature universal tension and compression cells, so the deciding factors are usually capacity and speed. The MLP reaches much higher capacities and is considerably stiffer, with a fixed low deflection and high natural frequency that make it the better choice for dynamic work or anything above 100 lb. The MDB offers tighter linearity and hysteresis specifications within its lower capacity range, which favors it for careful, slower, precision measurements. Tell us your force range and how fast the load changes and we'll point you to the right one.

My MLP was overloaded during setup — how do I know if it's still good?

The MLP's safe overload rating is 150% of rated capacity, so a brief excursion below that generally shouldn't cause harm. The usual evidence of a genuine overload is a zero that has shifted and won't return to its previous baseline, or readings that no longer match a known reference load. Check the unloaded zero against what you recorded when the sensor was new; if it has moved noticeably or won't settle, send it in for recalibration rather than continuing to trust the data.

Can I extend the Option-CO cable beyond 10 feet?

Longer runs add resistance in the excitation leads, which drops the voltage actually reaching the bridge and introduces a scaling error that grows with length. If you need more than the standard 10 feet, contact us about the right cable and whether your instrumentation supports remote sense connections to compensate for the drop — that's a much better answer than splicing in extra length and absorbing an unknown error.

My application sits near the aluminum-to-stainless boundary in the MLP range — does the material choice affect my measurement?

The published accuracy specifications are the same across the series regardless of material, so the choice is driven by capacity, environment, and mass rather than by measurement performance. Stainless variants weigh more, which matters if the sensor is mounted on something that moves, and they hold up better in humid or mildly corrosive conditions. Aluminum keeps the package lighter. If your capacity requirement falls where both are available, tell us about the environment and whether the cell will be in motion, and we'll recommend accordingly.